Ultra-Temp

®

Typical Installations ................................................................................................................3-4

Technical Data Sheet ..............................................................................................................5-6

Chimney Lengths ....................................................................................................................7-9

Elbows and Tees ................................................................................................................10-12

Supports ...........................................................................................................................13-17

Chimney Kits .....................................................................................................................18-19

Rain Caps/Storm Collar .....................................................................................................20-21

Flashings ...........................................................................................................................22-23

Shields ..............................................................................................................................24-25

Adapters ............................................................................................................................... 26

Accessories .......................................................................................................................27-29

TABLE OF CONTENTS

Summary of Contents for SELKIRK ULTRA-TEMP

Page 1: ...CHIMNEY CATALOG FUEL TYPE Gas Oil Wood Coal USA ONLY ...

Page 2: ...nstallations 3 4 Technical Data Sheet 5 6 Chimney Lengths 7 9 Elbows and Tees 10 12 Supports 13 17 Chimney Kits 18 19 Rain Caps Storm Collar 20 21 Flashings 22 23 Shields 24 25 Adapters 26 Accessories 27 29 TABLE OF CONTENTS ...

Page 3: ...n instructions for full and exact details of a correct installation DSP Stove Pipe Chimney Extension T 9 or Longer Finishing Collar T FC Wall Thimble IWT Chimney Clearance to Wall Use Locking Bands At Every Joint Wall Band T WB Needed Every 8 or Less Round Chimney Top T CT Storm Collar T SC 2 Flashing T AF6 or T AF12 8 Chimney Pipe Adapter CPA Tee Plug Wall Support Kit T WSK on Outside Wall The en...

Page 4: ...AIS Finish Support Pkg T FSP DSP Stove Pipe Joist Shield T JS Flashing T AF6 or T AF12 Either Full Enclosure in Attic or Attic Insulation Shield Round Top T CT Storm Collar T SC Full Enclosure in Occupied Areas Storage Areas or Closets Locking Bands at All Joints Finish Support Pkg T FSP All Connections Secured with Screws Solid Fuel Appliance Chimney Pipe Adapter CPA DSP Stove Pipe Locking Band 2...

Page 5: ...rior Resupport IR 18 18 Support Box SB 20 The Selkirk Chimney System SCS is ideal for venting residential heating appliances burning wood 2 oil and natural and LP gas They have been specifically designed for today s modern high efficiency airtight wood stoves They are designed for gravity natural draft nonpositive internal pressure venting only The SCS is usable on any appliance having a power bur...

Page 6: ...45 52 59 66 73 80 87 94 101 108 6 36 36 42 48 54 60 66 72 78 84 90 96 5 36 36 39 44 49 54 59 64 69 74 79 84 4 36 36 36 40 44 48 52 56 60 64 68 72 3 36 36 36 36 39 42 45 48 51 54 57 60 2 36 36 36 36 36 36 38 40 42 44 46 48 1 36 36 36 36 36 36 36 36 36 36 36 36 ULTRA TEMP GALVA TEMP All Fuel Chimney 2 ft 2 ft 10 ft Roof with Ridge Flat Roof 3 ft Step 1 Multiply the upper part from the pitch of roof ...

Page 7: ...6G 12GT 36 1 14 12 14 16 214012G 14GT 12 1 18 14 16 214018G 14GT 18 1 24 14 16 214024G 14GT 24 1 36 14 16 214036G 14GT 36 2 INSULATED LENGTHS GALVA TEMP Stainless steel inner and galvanized outer pipe All insulated pipe lengths are furnished with a Locking Band Secure twist lock design couples chimney sections together with just a 1 8 turn To calculate installed length subtract 1 1 4 per joint Ins...

Page 8: ...6UT 48 1 7 6 7 9 207006U 7UT 6 1 9 7 9 207009U 7UT 9 1 12 7 9 207012U 7UT 12 1 18 7 9 207018U 7UT 18 1 24 7 9 207024U 7UT 24 1 36 7 9 207036U 7UT 36 1 48 7 9 207148U 7UT 48 1 8 6 8 10 208006U 8UT 6 1 9 8 10 208009U 8UT 9 1 12 8 10 208012U 8UT 12 1 18 8 10 208018U 8UT 18 1 24 8 10 208024U 8UT 24 1 36 8 10 208036U 8UT 36 1 48 8 10 208148U 8UT 48 1 INSULATED LENGTHS ULTRA TEMP Stainless steel inner a...

Page 9: ...2 10 12 210012U 10U 12 1 18 10 12 210018U 10U 18 1 24 10 12 210024U 10U 24 1 36 10 12 210036U 10U 36 1 12 6 12 14 212006U 12U 6 1 9 12 14 212009U 12U 9 1 12 12 14 212012U 12U 12 1 18 12 14 212018U 12U 18 1 24 12 14 212024U 12U 24 1 36 12 14 212036U 12U 36 1 14 6 14 16 214006U 14U 6 1 9 14 16 214009U 14U 9 1 12 14 16 214012U 14U 12 1 18 14 16 214018U 14U 18 1 24 14 16 214024U 14U 24 1 36 14 16 2140...

Page 10: ... A 204206 N A 1 5 11 5 8 3 1 16 205206 5T EL 15 KIT 1 6 11 5 8 3 1 16 206206 6T EL 15 KIT 1 7 12 1 2 3 3 16 207206 7T EL 15 KIT 1 8 12 5 8 3 5 16 208206 8T EL 15 KIT 1 10 13 5 8 3 9 16 210206 10S EL 15 KIT 1 12 14 5 8 3 13 16 212206 12S EL 15 KIT 1 14 15 5 8 4 1 8 214206 14S EL 15 KIT 1 GALVA TEMP Size A B Product No Part No Pack 6 11 5 8 3 1 16 206206G 6GT EL 15 KIT 1 7 12 1 2 3 3 16 207206G 7GT ...

Page 11: ...2 97 52 78 7GT UT 15 0 88 8 75 2 10 13 34 2 88 16 24 3 66 19 13 5 21 24 93 6 76 30 72 9 87 42 32 12 97 53 91 8GT UT 15 1 00 8 25 2 23 12 84 3 01 15 74 3 78 18 63 5 34 24 43 6 89 30 22 9 99 41 82 13 10 53 41 5GT UT 30 3 13 13 38 5 50 17 49 7 00 20 09 8 50 22 68 11 50 27 88 14 5 33 08 20 50 43 47 N A N A 6GT UT 30 3 00 12 50 5 38 16 61 6 88 19 21 8 38 21 81 11 38 27 01 14 38 32 20 20 38 42 59 26 38 ...

Page 12: ...IT 1 10 8 3 8 8 3 8 16 3 4 210100 10S IT 1 12 9 3 8 9 3 8 18 3 4 212100 12S IT 1 14 10 3 8 10 3 8 20 3 4 214100 14S IT 1 GALVANIZED TEE W INSULATED TEE PLUG Size A B C Product No Part No Pack 6 6 3 8 6 3 8 12 3 4 206100G 6GT IT 1 7 6 7 8 6 7 8 13 3 4 207100G 7GT IT 1 8 7 3 8 7 3 8 14 3 4 208100G 8GT IT 1 Note 4 Insulated Tee not exactly as shown INSULATED TEE PLUG Size A B C Product Code Part No P...

Page 13: ...K This new design gives you the flexibility of securing the 5 6 7 or 8 diameter chimney with a heavy duty band The band allows you to slide the installed length vertically to properly position this section in the system Installation requirements are the same as our standard RSP The URSA can hold 30 of pipe total up to 20 can be below ULTRA TEMP Size A B Framing Product No Part No Pack 4 4 6 10 x t...

Page 14: ...ertical Feet at 2 from Wall The Type HT Wall Support Kit has been tested for use fully enclosed and has been designed in 5 6 7 and 8 sizes to carry up to 60 of height The capacity of the larger sizes 10 12 and 14 is 40 of chimney The Wall Support is intended for use with the Insulated Tee as an interior or exterior support where the chimney has a lateral connection It is also useful where the pipe...

Page 15: ... 22 5 8 10 0805900 UEWS 1 INTERIOR RESUPPORT Size Product No Part No Pack 4 HT4IOS N A 1 5 205435 5T IR 1 6 206435 6T IR 1 7 207435 7T IR 1 8 208435 8T IR 1 10 210435 10S IR 1 12 212435 12S IR 1 14 214435 14S IR 1 Required to support offset at the immediate section of chimney above the upper elbow of an offset Will support 25 of 4 diameter chimney For diameters from 5 to 14 it will support 18 Stra...

Page 16: ...30 UTCR 1 Supports continued CSPR FSPR CSP FSP Black Matte Finish ROUND CEILING SUPPORT O D Framing Dimensions Round Plate Dimensions From Ceiling Dim A Dim B Dim C Dim D Product No Part No Pack 5 1 4 11 1 4 x 11 1 4 17 3 1 2 205411 5T CSPR 1 6 1 4 12 1 4 x 12 1 4 19 3 1 2 206411 6T FSPR 1 8 1 4 14 1 4 x 14 1 4 22 3 1 2 208411 8T FSPR 1 SQUARE CEILING SUPPORT O D Framing Dimensions Square Plate Di...

Page 17: ... provides a finished installation at the ceiling level and will support up to 20 of 6 7 or 8 diameter chimney The part also provides shielding from insulation when installed in an unoccupied attic space The Support Box assembly is comprised of a black box designed for installation inside 16 O C joists a cylindrical shield support bucket ceiling trim and four screws ANCHOR PLATE ANCHOR PLATE WITH D...

Page 18: ...o provide required stability for your chimney above the roof An Attic Insulation Shield is a required part of the installation even if you have no insulation in the area where your chimney passes through the attic The only exception to this AIS installation is if you install a full enclosure around the chimney in the attic area at the minimum two inch clearance FLAT CEILING SUPPORT KIT FCK Size Pr...

Page 19: ...chimney height One Wall Band WB is included in the kit Additional Wall Bands could be required if your vertical chimney run is more than 16 feet high In the event that your vertical chimney run penetrates the roof eave your installation could also require an Adjustable Flashing AF and Storm Collar SC Depending on the height of pipe above the roof a Roof Brace Kit may be required See page 14 PITCHE...

Page 20: ...llar Size A B C Product No Part No Pack 4 4 11 7 1 2 HT4RC N A 1 5 7 10 5 205800 5T CT 1 6 8 12 5 1 2 206800 6T CT 1 7 9 14 6 1 4 207800 7T CT 1 8 10 16 7 208800 8T CT 1 10 10 20 8 1 2 210800 10S CT 1 12 12 24 10 212800 12S CT 1 14 14 28 11 1 2 214800 14S CT 1 Size A B C Product No Part No Pack 10 12 16 10 210804 10S EZCTS 1 12 14 20 12 212804 12S EZCTS 1 14 16 20 12 214804 14S EZCTS 1 4 ULTRA TEM...

Page 21: ...proofed with non hardening silicone caulking to prevent any water from leaking between the Storm Collar and chimney pipe Part is tightened with screws or tabs after positioning Size A Product No Part No Pack 4 6 HT4SC N A 5 6 7 8 206810 5 6T SC 6 7 8 9 10 208810 7 8T SC 6 10 12 210810 10S SC 1 12 14 212810 12S SC 1 14 16 214810 14S SC 1 A Note 4 Storm Collar not exactly as shown Ultra Temp ...

Page 22: ... 7 8 27 207830 7TAF 12 1 8 10 1 8 19 7 8 31 7 8 27 208830 8TAF 12 1 10 12 1 8 25 1 2 31 1 2 36 210830 10SAF 12 1 12 14 1 8 28 1 2 40 1 2 36 212830 12SAF 12 1 14 16 1 8 31 1 2 43 1 2 36 214830 14SAF 12 1 Note All TF flashings come with a roof shield set 4 TCF not exactly as shown 2 12 To 6 12 Pitch 6 12 To 12 12 Pitch Note For 5 inch chimney use 6 inch Selkirk Flashing with 5 6 inch storm collar Al...

Page 23: ...o Part No Pack 200280 URFK 1 12 12 To 24 12 Pitch 24 12 To 36 12 Pitch Dead Soft Flashing for 6 12 to 12 12 Note For 5 inch chimney use 6 inch Selkirk Flashing with 5 6 inch storm collar All Flashings have 025 Aluminum Bases Note Dead Soft Aluminum base is designed to be molded to uneven roof surfaces Note Used for installations on corrugated roofs flat to 12 12 10 12 for 8 pitch Kit includes rubb...

Page 24: ... down Joist Shield is included for use when the chimney is enclosed below the ceiling Refer to instructions for full details The Attic Insulation Shield acts as an insulation shield to keep blown in or blanket insulation from filling in any framed opening or contacting the chimney Size A B C D E Product No Part No Pack 4 10 6 N A 12 N A HT4AIS N A 1 5 11 7 13 11 13 16 8 1 2 205490 5T AIS 1 6 12 8 ...

Page 25: ...2S JS 1 14 22 18 16 1 8 214465 14S JS 1 Note 4 Firestop Radiation Shield not exactly as shown A 12 C B Shields continued SUSI SELKIRK UNIVERSAL SHIELDING INSULATION Optional insulation for use with the Support Box Attic Insulation Shield and Insulated Wall Thimble The SUSI protects building materials against radiant heat from the chimney and helps maintain temperatures within the chimney system Th...

Page 26: ... this part can be installed by twist locking the coupler on the DSAC into the first section of Ultra Temp or Galva Temp Type HT chimney pipe Size A B Product Code Part No Pack 6 5 15 16 15 3 4 206240 6T DSAC 1 7 6 15 16 15 3 4 207240 7T DSAC 1 8 7 15 16 15 3 4 208240 8T DSAC 1 Note DSAC is 430 Stainless Steel DRIPLESS STOVE PIPE ADAPTER DSA For use in retrofit installations this part can be instal...

Page 27: ...1 14 16 20 214520 14S WB 1 WALL BAND UNIVERSAL ADJUSTABLE WALL BAND The Universal Adjustable Wall Band is used along the wall to provide for 2 inch clearance and assure stability Required at 8 foot or closer intervals above the tee to stabilize the chimney Fits chimney diameters from 5 to 8 Size Product Code Part No Pack 5 6 7 8 200270 UWB 1 Designed to deflect snow and ice while preventing unnece...

Page 28: ...PAJ 1 7 17 1 2 20 31 207512 7T PCPAJ 1 8 18 1 2 21 33 208512 8T PCPAJ 1 10 20 1 2 23 37 210512 10S PCPAJ 1 12 22 1 2 25 41 212512 12S PCPAJ 1 14 24 1 2 27 45 214512 14S PCPAJ 1 Size A B Product Code Part No Pack 6 16 1 2 19 30 206514 6T PCPAJ12 1 7 17 1 2 20 31 207514 7T PCPAJ12 1 8 18 1 2 21 33 208514 8T PCPAJ12 1 10 20 1 2 23 37 210514 10S PCPAJ12 1 12 22 1 2 25 41 212514 12S PCPAJ12 1 14 24 1 2...

Page 29: ...extended down into the room Used to trim the wall when chimney passes through a non combustible wall Used in conjunction with the Firestop Joist Shield Black Matte Finish Size A B C Product Code Part No Pack 5 17 11 7 1 8 205488 5T TPS 1 6 19 12 8 1 8 206488 6T TPS 1 7 21 13 9 1 8 207488 7T TPS 1 8 22 14 10 1 8 208488 8T TPS 1 C A B C A B Ultra Temp ...

Page 30: ...Notes ...

Page 31: ...Notes ...

Page 32: ...ooftop products residential vent filters duct components grilles registers diffusers commercial industrial vent Complete Linecard roof curbs equipment rails Selkirk USA 4460 44th Street SE Suite F Grand Rapids MI 49512 phone 1 800 992 VENT 8368 email info selkirkcorp com selkirkcorp com Selkirk Canada P O Box 526 Depot 1 Hamilton ON L8L 7X6 phone 1 888 SELKIRK 735 5475 email cscanada selkirkcorp c...