en
II
I
WH_M_DuraSolid_FST/17.03.4
7
Electrical installation
L
N
PE
10
connecting the whirltub (Diagram 10)
NotIcE
Malfunctions due to incorrect
installation!
> Do not fasten the cables together with cable ties.
> Do not install the supply line parallel to the control
cables.
I
Connect the supply line to the mains supply socket.
II
Connect the potential equalisation cable to the
whirltub.
* or the height
of the highest
shower head /
water outlet that
is permanently
installed,
depending on
which is higher
Pre-Installation
> Installing a permanent power supply line:
•
Install separate circuit breaker and residual-current
circuit breaker (RCCB) upstream
•
Connect all pole disconnector mains switch upstream
located outside specified protection zones (0 - 2)
•
Leave 3000 mm of feed cable exposed
> Laying an equipotential bonding cable:
•
Leave 3000 mm of cable exposed
Safety areas in accordance with DIN VDE 0100-701
600
600
2250*
0
1
2
76xxxx xx x xx xx00: 50 Hz, 220 - 240 V AC
76xxxx xx x xx xx06: 60 Hz, 220 - 240 V AC
I
N
= 16 A
I
ΔN
≤ 30 mA
Power supply
Circuit breaker
RCCB