en
Important information
Mounting instructions information
These mounting instructions come as part of the Duravit
whirltub and should be read carefully prior to installation.
Explanation of the key words and symbols
DANGER
Indicates a hazardous situation which,
if not avoided, will result in death or
serious injury.
NOTICE
Is used to address practices not related
to physical injury.
Link to the
Electrical installation
section
Link to the
mounting information
in this section
Inspection (e.g. for scratches)
Indication of the length of time (e.g. 10 minutes)
Inspect to check for leaks and leaktightness
Indication of the temperature
Target readership and qualifications
The whirltub must only be installed by trained plumbing
engineers. The electrical installation should only be carried
out by qualified electricians.
NOTICE
Risk of product and/or property
damage!
> Observe the local installation regulations and any
countryspecific standards at all times.
Safety instructions
DANGER
Risk of fatal electric shock!
> Do NOT remove any whirltub components.
Mounting instructions
Please read preinstallation information sheets prior to
the installation. These are available to download on the
Internet at www.duravit.com.
NOTICE
If the tray has a base inlet, a pipe
interrupt must always be installed on
site. (DIN EN 61770, DIN EN 1717)
> See installation diagram.
Seitenansicht
Lateral view
150
> =
Gezeichnet
Drafted
Ge ndert
Modified
Gepr ft
Certified
Datum
Date
Name
Ma§stab
Scale
Name
Bezeichnung
Description
Artikel-Nr.
Model-No.
Technische Verbesserungen und optische Ver nderungen an den abgebildeten Pr
odukten behalten wir uns vor.
We reserve the right to mak
e technical improvements and enhance the appearance of the pr
oducts shown.
1:20
1:10
1:5
X
# W-
T
-
Allgaier
000000 - 00 - 0
08.10.13
000000
Schematische Zeichnung mit Rohrunterbr
echer
Zeichnung
Drawing
Spezial Ab-und berlaufgarnitur mit Bodenzulauf
f r Badewanne
Special waste and overflow with base inle
t
for bathtubs
WLT
08.10.13
20
Checking the whirl system (Diagram 20)
>
Switch on the whirl system for 10 minutes:
Run this through once completely in the case of
circuits with different levels of intensity.
>
Leave the water in the bathtub and wait 10
minutes.
>
Check to make sure that it is leaktight.
>
If adjustments are required, repeat the check.
21
Providing for an inspection hatch (Diagram 21)
Install the whirltub such that all vital assemblies
(pump, air blower and controls) remain accessible
>
Providing for inspection hatches
• Dimensions of the inspection hatches
for assemblies: min. 50 x 50 cm
for drain fittings: min. 20 x 20 cm
• Sealed to avoid spray water
• Only to be opened with a tool
22
Providing for an air supply (Diagram 22)
>
Provide for an opening on the panel with an area
of approx.15 cm
2
(e.g. 3 x 5 cm or 2 x 7.5 cm) for the air supply.
6
WH_M_BlueMoon_builtin/21.04.3
Summary of Contents for Blue Moon 760143
Page 2: ...Blue Moon 760143 760402 2 WH_M_BlueMoon_built in 21 04 3...