en
WH_M_BlueMoon_FST_with panel/17.10.2
7
Electrical installation
L
N
PE
12
Connecting the whirltub (Diagram 12)
NOTICE
Malfunctions due to incorrect
installation!
> Do not fasten the cables together with cable ties.
> Do not install the supply line parallel to the control
cables.
I
Connect the supply line to the mains supply socket.
II
Connect the potential equalisation cable to the
whirltub.
* or the height of
the highest shower
head / water outlet
that is permanently
i n s t a l l e d ,
depending
on
which is higher
Pre-Installation
> Installing a permanent power supply line:
• Install separate circuit breaker and residual-current cir-
cuit breaker (RCCB) upstream
• Connect all pole disconnector mains switch upstream
located outside specified protection zones (0 - 2)
• Leave 3000 mm of feed cable exposed
> Laying an equipotential bonding cable:
• Leave 3000 mm of cable exposed
Safety areas in accordance with DIN VDE 0100-701
600
600
2250*
0
1
2
76xxxx xx x xx xx00: 50 Hz, 220 - 240 V AC
76xxxx xx x xx xx06: 60 Hz, 220 - 240 V AC
I
N
= 16 A
I
Δ
N
≤
30 mA
Power supply
Circuit breaker
RCCB
II
I
Summary of Contents for Blue Moon 760402
Page 2: ...Blue Moon 760143 760402 2 WH_M_BlueMoon_FST_with panel 17 10 2...
Page 60: ...760143 760402 703045 BM8750 60 WH_M_BlueMoon_FST_with panel 17 10 2...
Page 61: ...10 x mm 8 8 8 8 x 1 2 2 7 6 5 3 4 WH_M_BlueMoon_FST_with panel 17 10 2 61...
Page 62: ...8x 1 2 3 4 5 6 6 8 16 15 14 13 12 11 10 9 8 62 WH_M_BlueMoon_FST_with panel 17 10 2...
Page 63: ...18 19 703045 8750 703045 17 17 8750 18 WH_M_BlueMoon_FST_with panel 17 10 2 63...