60
0
600
2250*
0
1
2
L
N
PE
Electrical installation
II
I
*
or the height of
the highest shower
head / water outlet
that is permanently
installed; depending
on which is higher
Safety areas in accordance with DIN VDE 0100-701
7xxxxx xx x xx xxx0: 50 Hz, 220 - 240 V AC
7xxxxx xx x xx xxx6: 60 Hz, 220 - 240 V AC
I
N
= 16 A
I
ǻ1
P$
Power supply
Fuse protection
RCD
Pre-installation
> Installing a permanent power supply line:
ιϟ
Pre-connect a separate fuse and residual
current operating device (RCD)
ιϟ
Pre-connect an all-pole separating main switch
outside the prescribed safety areas (0 - 2)
ιϟ
Allow the supply line to protrude by 3,000 mm
> Laying the potential equalisation cable:
ιϟ
Allow the cable to protrude by 3,000 mm
15
Connecting the whirltub (Diagram 15)
NOTE! Avoiding any malfunctions!
ιϟ
Do not fasten the cables together with cable ties.
ιϟ
Do not install the supply line parallel to the control
cables.
I
Connect the supply line to the mains supply
socket.
II
Connect the potential equalisation cable to the
whirltub.
WH_M_D-Code_Fliesen/17.04.3.
7
en