20
Set units
> Press the
“
Off
”
or
“
On
”
button until the correct unit is displayed.
> Press the
“
OK
”
button to confirm the units.
“
Nominal
”
is displayed on the operator's panel.
Adjust nominal temperature
> Press the
“
Off
”
or
“
On
”
button until the desired value is displayed.
> Press the
“
OK
”
button to confirm the value.
“
PIN-request
”
is displayed on the operator's panel - the first digit flashes.
Set PIN
The Settings menu and the ECO/Standby-mode can be protected by activating the PIN
function. If you do not want to do this, you can deactivate it by selecting
“
0000
”
as the
PIN.
> Press the
“
Off
”
or
“
On
”
button until the required digit is displayed.
> Press the
“
OK
”
button to confirm the digit.
The next digit flashes on the operator's panel.
> Repeat this procedure until all four digits of the PIN have been changed.
The operator's panel is now configured. The actual and nominal temperatures are
displayed on the operator's panel.
Step 4: Fill pool
> Fill the pool with tap-water (water temperature <40 °C; water hardness of
1-1.5 mmol/l (5.6-8.4°dH)) until the water level is about 50 mm above the upper-
most jet.
> Wait until the pool is completely filled.
> When it is completely filled the water changing cycle starts for one minute and
“
Wa-
ter Changing Activated
”
appears on the operator's panel.
> Wait for another three minutes until the hygiene and temperature circuit starts
automatically.
> The
“
Hygiene
”
button lights up.
Step 5: Safeguard water-quality
Check the water quality in accordance with the steps listed in the chapter
“
Water
Treatment
”
.
> Repeat your water quality check as soon as the water has reached the normal tem-
perature that has been set.
The pool is now configured and ready, you can enjoy your first bath!