41
11.5 Inhibit algae development
NOTICE
Air inclusions may cause damage to the whirl system.
•
Only use foam free algae inhibitors.
> Add BAYROL Desalgin Jet to the bathing water in accordance with the manufacturer's
instructions.
> Remove any surface contaminants such as leaves immediately as these encourage
the development of algae and microbial contamination of the water.
11.6 Change filter (minimum twice per year)
NOTICE
•
If you have more than the regular number of bathers or if you forget to cover the
pool and if it is outdoors then inspect the filter earlier and change as necessary.
•
The pool must only be used when the exchangeable cartridge that is in place and
must never be used without a cartridge.
The diagrams referred to are collected together in the chapter
“
Diagrams and Pic-
tures
”
.
> Press the
“
Hygiene
”
button on the operator's panel to stop the hygiene and tempera-
ture circuit (this starts again automatically after one hour).
The
“
Hygiene
”
button flashes.
> Remove the acrylic/wooden liner (
6
- Blue Moon) and/or the padded cover (Sun-
deck).
> Remove the white cover over the fine filter
(5)
.
> Pull the tab upwards and turn the screw of the fine filter
(5)
in anti-clockwise mo-
tion (Fig. 1; Chapter 5) and remove it. (Fig. 2; Chapter 5)
> Remove the cover completely. (Fig. 3; Chapter 5)
> Remove the fine filter cartridge. (cf. Fig. 4; Chapter 5)
> Clean fine filter housing
(5)
with a damp cloth.
> Replace the air valves in the cover of the fine filter housing. New valves are included
with the new filter cartridge.
> For this, unscrew and remove the gland of the silicone valve from the cover. (Fig. 6)
> Pull out the blue silicon valve.
> Carefully insert a new silicone valve from inside into the gland.
> Screw the gland again into the cover.