When using the polisher for long periods of time, check the polishing pad for wear.  

2

Replace worn pads as worn or clogged pads will make the polisher inefficient.

3

The polishing operation will cause heat.  Check the material that is being worked on that 
it is not getting too hot.  If this is occurring, stop polishing to allow the material to cool 
down.

4

You can adjust the speed of the tool by adjusting the pressure you apply to the throttle.

5

Make regular checks on the polishing pad for wear and damage and replace them 
immediately.

6

Due to the potential heat caused by the polishing process, keep flammable liquids and 
gases well away from the work area. 

Maintenance

1

Remove plug from the mains power supply before carrying out any maintenance or cleaning.

Every 50 hours of operation blow compressed air through the motor while running at no load to clean
out accumulated dust. If operating in especially dusty conditions, perform this operation more often.

Periodically blow out all air passages with dry compressed air.

All plastic parts should be cleaned with a soft damp cloth. NEVER use solvents to clean plastic parts.
They could possibly dissolve or otherwise damage the material.

Wear safety glasses while using compressed air.

Carbon Brushes

The carbon brushes are a normal wearing part and must be replaced when they reach their wear 
limit. NOTE: Checking and replacing the carbon brushes should be entrusted to a qualified service 
centre. The carbon brushes furnished will last approximately 50 hours of running time or 10,000 on/off 
cycles.  Replace 

both

carbon brushes when either has less than 1/4" length of carbon remaining.

2

Warning

The tool should be unplugged.  

3

Unscrew three screw ST3*20. (FIG 8)

4

Open the machine body. 

5

Pull out the insert spring with pliers(A), and move the coil spring(B). (FIG 9), Pull out the Carbon 
brush(A) from the brush holder.(FIG 10)

6

Pull in the Carbon brush into the brush holder, move back the coil spring, then pull in the insert spring 
with pliers. Fold the left and right housing, tighten the screw.

7

Warning

Never extrude the internal cord when you fold the left and right housing to avoid the 

damage of insulating of cable.   

Environmental Protection (W.E.E.E.)

The Waste Electrical & Electronic Equipment Regulations (WEEE) requires that any of our products
showing this marking (left) must not be disposed of with other household or commercial waste. To
prevent possible harm to the environment or human health from uncontrolled waste disposal, please
separate any such product from other waste types and recycle it responsibly at your local facilities.
Check with your Local Authority, Recycling Centre or retailer for recycling advice.

321287_Product Instructions  30/07/2014  08:42  Page 5

Summary of Contents for 321287

Page 1: ...www duren co uk Part Code 321287 240V Electric 150mm Dual Action Polisher Product Instruction Manual PLEASE KEEP THIS MANUAL SAFE FOR FUTURE REFERENCE 321287_Product Instructions 30 07 2014 08 42 Page 1 ...

Page 2: ...the tool The tool starts as soon as the Power Switch is activated 2 The switch does not need pressure applied to stay in the on position The switch is pressed again to turn off the tool 3 Two handed operation is recommended at all times IMPORTANT Please read through this Manual carefully before using the 321287 This tool must only be used for polishing and within the parameters outlined in this ma...

Page 3: ...ensure that they are safe 2 You MUST inspect plugs sockets power leads and any other connectors for wear or damage 3 You MUST have any worn or damaged plugs sockets and power leads replaced immediately upon discovery 4 You MUST ensure that the risk of electric shock is minimised by the installation of appropriate safety devices 5 A Residual Current Circuit Breaker RCCB should be incorporated in th...

Page 4: ...aint the following actions must be observed Alert any other persons in the nearby and keep them away from the working area Use specific air fed respirator PE coated coveralls and latex gloves Dispose of any dust and paint waste correctly and thoroughly clean the workpiece and working area after the polishing has finished 11 NEVER attempt to sand materials containing asbestos 12 VIBRATION Hand elec...

Page 5: ...e material 5 Wear safety glasses while using compressed air Carbon Brushes 1 The carbon brushes are a normal wearing part and must be replaced when they reach their wear limit NOTE Checking and replacing the carbon brushes should be entrusted to a qualified service centre The carbon brushes furnished will last approximately 50 hours of running time or 10 000 on off cycles Replace both carbon brush...

Page 6: ...lts caused by incorrect installation assembly Repairs or alterations carried out by non approved parties Validity This warranty is valid for 6 months after date of purchase Warranty is rendered invalid if Tool is taken apart for any reason without our consent The points in the Electrical and General Safety Instructions are not observed A warranty claim will not be accepted without an official proo...

Page 7: ...7 22 Spring Washer 4 23 321287 23 Shield 1 24 321287 24 Bearing Washer 1 25 321287 25 Screw 3 26 321287 26 Upper Eccentricity 1 27 321287 27 Eccentric Washer 1 28 321287 28 Washer 1 29 321287 29 Screw 1 30 321287 30 Check Ring 1 No Code Description Q ty 31 321287 31 Bearing 2 32 321287 32 Shaft 1 33 321287 33 Lower Eccentricity 1 34 321287 34 Washer 3 35 321287 35 Screw 3 36 321287 36 Rotating Pla...

Page 8: ...s T 01582 484875 E sales duren co uk www duren co uk Copyright c 2014 Duren Tools No part of this manual may be copied or altered without the permission of the owners of the Duren brand 321287_Product Instructions 30 07 2014 08 42 Page 8 ...

Reviews: