background image

12/24V 12A Digital Battery Charger - NORM, AGM, STD, GEL 

& Li-Ion 

Part 0-647-42

0-647-42-LEAF

www.durite.co.uk

    GENERAL

Before using this unit please read these instructions carefully. Take special care to follow

the warnings and safety suggestions listed below. Keep these instructions for future refer-

ence. There are no user-serviceable parts within the unit, refer servicing to qualified service

personnel.

IMPORTANT SAFETY INSTRUCTIONS

1. This appliance is not intended for use by persons (including children) with reduced phys-

ical, sensory or mental capabilities, or lack of experience and knowledge, unless they have

been given supervision or instruction concerning use of the appliance by a person respon-

sible for their safety. Children should be supervised to ensure that they do not play with the

appliance.

2. Working in vicinity of a lead-acid battery is dangerous. Batteries generate explosive gases

during normal battery operation. For this reason, it is of utmost important that each time

before using your charger, you read this manual and follow the instruction exactly.

3. To reduce risk of battery explosion, follow these instructions and those published by the

battery manufacturer and manufacturer of any equipment you intend to use in vicinity of

battery. Review cautionary markings on these products and on engine

4.Use the charger in door only, do not expose it to rain.

Summary of Contents for 0-647-42

Page 1: ...owledge unless they have been given supervision or instruction concerning use of the appliance by a person respon sible for their safety Children should be supervised to ensure that they do not play with the appliance 2 Working in vicinity of a lead acid battery is dangerous Batteries generate explosive gases during normal battery operation For this reason it is of utmost important that each time ...

Page 2: ... gas 11 Locate charger as far away from battery as DC charger cable s permit 12 Do not expose charger to rain or snow 13 NEVER charge a frozen battery If battery fluid electrolyte is frozen bring into a warm area to thaw before charging 14 NEVER allow battery acid to drip on charger when reading specific gravity or filling bat tery 15 NEVER set a battery on top of charger 16 NEVER place charger di...

Page 3: ...e of battery connect black clamp O ring to negative of battery 3 Please remove the plug from the AC socket before disconnect the battery then remove the clamp O ring from battery Charging for car battery 1 Please put AC plug into AC socket 2 Please choose correct charging mode according to battery rated voltage and battery type press the Enter Exit button to start charging If changing charge mode ...

Page 4: ...ging 2 LCD Screen display working codes and icons 3 BatteryType Selection STD AGM GE LITHIUM 4 Voltage Selection Button 6V 12V 5 Current Selection Button 0 8A 2A 4A automatic selection 6 Charging Mode Selection Button Auto Mode Recond Mode Winter Mode Supply Mode Maintain Mode ...

Page 5: ...rent 4 Constant Voltage Charging battery to 75 capacity by Constant Voltage 5 Analysis Analyzing power capacity if can not store power the battery should be replaced 6 Recond Restores power capacity in a stratified battery to sustain ultimate battery life 7 Float charge Charging battery to 100 capacity by Constant Voltage and keep battery voltage with maximum level 8 Diagnosis To check if battery ...

Page 6: ...ge mode automatically when temperature recovers to the normal condition a When charger used long time under high temperature b When inside temperature of charger reaches the present temperature 4 Over voltage protection 5 Fire protection There is no output in the clamp when disconnected with battery 6 Low voltage activation The charger will enter the charge mode automatically when voltage of end o...

Page 7: ... temperature protection 3 Check to see if wrong voltage of battery selected 4 Send the charger to professional person to test Power indicator not illuminated when charger is working Faulty LED indicator 6V or 12V indicator not illuminated when charger is working Faulty LED indicator 6V 12V can t switched or not sensitive 1 The operation is improper when using the switch 2 Switch was damaged Type D...

Reviews: