3.4
Removing the cable
The cable that runs from the output “ST2” on the control unit to the
input “X11” on the PCB must be dismantled and replaced by the
cable harness that is part of the kit.
–
Remove the cable tie 1.
–
Unscrew the clip 4.
–
Pull the plug 2 off the PCB.
–
Run the cable 4 downwards through the table top.
–
Pull the cable’s plug off the control unit.
Anbauanleitung für Teilesatz "Sauberer Nahtanfang"
0867 591004
Fitting Instruction for "Neat Seam Beginning"
0867 591004
Teile-Nr./ Part-No.:
0791 867708
Blatt:
von
Sheet: 18 from 24
Ausgabe/Edition:
06.2010
Änderungsindex
Rev. index: 00.0
Printed in Germany
1
2
4