Machine head
Service Instructions 745-35-10 D - 00.0 - 10/2017
37
Fig. 26: Assembling the needle bar linkage (2)
7.
Tighten the guide plate (10) using the screws (9).
8.
Insert the needle and align the needle bar linkage (2) with the throat
plate.
9.
Tighten the screw (5).
10. Check the height of the needle bar linkage (
lateral alignment with the needle hole (
Fig. 27: Assembling the needle bar linkage (3)
11. Slide the thread advancing device (13) onto pins (15) and (12).
12. Tighten screws (14) and (11).
13. Set the thread advancing device (13) (
(9)
- Screws
(10) - Guide plate
⑨
⑩
(11) - Screw
(12) - Pin
(13) - Thread advancing device
(14) - Screw
(15) - Pin
⑫
⑪
⑬
⑮
⑭
Summary of Contents for 745-35-10 D
Page 1: ...745 35 10 D Service Instructions...
Page 6: ...Table of Contents 4 Service Instructions 745 35 10 D 00 0 10 2017...
Page 10: ...About these instructions 8 Service Instructions 745 35 10 D 00 0 10 2017...
Page 74: ...Machine head 72 Service Instructions 745 35 10 D 00 0 10 2017...
Page 84: ...Transport carriage 82 Service Instructions 745 35 10 D 00 0 10 2017...
Page 116: ...Light barriers 114 Service Instructions 745 35 10 D 00 0 10 2017...
Page 122: ...Aligning the machine head 120 Service Instructions 745 35 10 D 00 0 10 2017...
Page 128: ...Folder 126 Service Instructions 745 35 10 D 00 0 10 2017...
Page 146: ...Throw over stacker 144 Service Instructions 745 35 10 D 00 0 10 2017...
Page 282: ...Programming 280 Service Instructions 745 35 10 D 00 0 10 2017...
Page 292: ...Maintenance 290 Service Instructions 745 35 10 D 00 0 10 2017...
Page 294: ...Decommissioning 292 Service Instructions 745 35 10 D 00 0 10 2017...
Page 296: ...Disposal 294 Service Instructions 745 35 10 D 00 0 10 2017...
Page 308: ...Troubleshooting 306 Service Instructions 745 35 10 D 00 0 10 2017...
Page 337: ......