Working basis
Service Instructions 1767 - 00.0 - 12/2016
25
There are 2 securing positions:
•
Securing position 1
: Loop stroke position
• 5 mm end in the large slot
• Setting the loop stroke and needle bar height
•
Securing position 2
: Handwheel zero position
• 3 mm end in the small slot
• Setting the handwheel position and checking the top dead center
for the needle bar
Fig. 13: Locking the machine in place (2)
Locking the machine in place
To lock the machine in place:
1.
Remove the plug from the locking opening (6).
2.
Turn the handwheel until the appropriate slot (5) is in front of the locking
opening (6):
• Small slot at handwheel position 0°
• Large slot at handwheel position 200 – 205°
3.
Insert the locking peg (7) with the appropriate end into the slot (5).
Removing the lock
To remove the lock:
1.
Pull the locking peg (7) out of the slot (5).
2.
Insert the plug into the locking opening (6).
(5)
- Slot
(6)
- Locking opening
(7)
- Locking peg
⑦
⑤
⑥