Zigzag stitch mechanism of machines 523, 524, 527
Service Instructions 52Xi, 52Xi-75 - 00.0 - 11/2021
23
4.5
Lateral setting of needle stab position
Proper setting
Both dead centers of the needle lateral motion at the zigzag stitch sewing
should be at the same distance from the throat plate needle hole edges.
Pic. 14: Lateral setting of needle stab position
6.
Dismantle the cover (1) and the hole stop (3) from the rear side.
7.
Loosen both screws (2).
8.
Set the maximum zigzag stitch width and adjust the positions of the
needle lateral motion dead centers as per proper setting.
9.
Tighten both screws (2) properly.
10. Replace the cover (1) and hole stop (3).
(1) - Cover
(2) - Screws
(3) - Hole
②
①
②
③