Maintenance work
Service manual 567 classic - 01.0 - 10/2015
75
19.3.2 Cleaning the motor fan mesh
The motor fan mesh must be cleaned once a month using a compressed
air gun. When very fluffy material is used for sewing, the motor fan mesh
must be cleaned more frequently.
Fig. 64: Cleaning the motor fan mesh
Cleaning steps
1. Sewing dust and fiber residues must be removed with a compressed
air gun.
19.4 Checking the toothed belt
The condition of the toothed belt must be checked once a month.
A damaged toothed belt must be replaced immediately.
WARNING
Risk of injury
Switch off the machine at the main power switch be-
fore cleaning the motor fan mesh.
Flying particles can get in the eyes, causing injury.
Hold the compressed air gun so that the particles
do not fly close to people.
2
1
(1) - Table plate
(2) - Motor fan sieve
WARNING
Risk of injury
Crushing injuries from moving parts.
Switch off the machine before checking the condi-
tion of the toothed belt.