Operating manual part II
II-10
© 2010 Dürkopp Adler AG
L
C
P
Min
Max
Preset Unity
Description
Thread tension
t
09 00 0
3
0
°
Mode of the thread tension release and thread tension
reduction with active foot lifting.
0 = No thread tension release;
1 = Thread tension release in the seam;
2 = Thread tension release after thread trimming;
3 = Thread tension release in the seam and after thread
trimming.
t
09 01 0
1
1
°
Thread tension release by thread he lp
0 = No;
1 = Yes
t
09 02 0,0
2,55
0,0
s
Delay time of the tread tension release after thread trimming.
(Only active if t 09 00 = 2 or 3)
t
09 10 0
359
50
°
on switching angle t 08 of 12 < = t of 09 10 < t 09 11 at the
trimming process
t
09 11 0
359
306
°
off switching angle t of 09 10 < t 09 of 11 < = t 08 13 at the
trimming process
t
09 20 0
255
0
ms
Delay time for a repeated activation of the tension magnet at
the trimming process.
t
09 21 0
255
40
ms
Delay time for turning the tension magnet off at the trimming
process
t
09 50 0
999
80
ms
Drive time of the thread tension magnet in the time period t
1
t
09 51 5
100
100
%
Pulse duty ratio in the time period t
1
t
09 52 0,0
600,0
60,0
s
Drive time of the thread tension magnet in the time period t
2
(If you adjust 0s the thread tension magnet will be driven
permanently)
t
09 53 5
100
70
%
Pulse duty ratio in the time period t
2
t
09 54 0
1
0
-
Increasing U
mag
when the thread tension magnet will be driven
0 = No;
1 = Yes
High lift for walking foot
t
10 00 0
1
0
-
High lift for walking foot
0 = No;
1 = Yes
t
10 01 0
9999
1800
rpm
High lift walking speed
t
10 02 1
21
10
Step
Lower speed break point
t
10 03 1
21
19
Step
Upper speed break point
t
10 04 -
-
-
-
Show the actual position of the potentiometer and the actual
limitation of the speed
3: 2800
3: = actual position
2800 = speed limitation
t
10 05 0
1
0
-
Operational mode of the high lift for walking foot
0 = not stored;
1 = stored