Storage Period
Storage Preparation
If you plan on starting
the same day.
1.
Allow the unit to run 3 - 5 minutes.
2.
Turn off the start switch.
3.
Store.
If you plan on starting
the unit again within
30 days.
1.
Allow the unit to run 3 - 5 minutes.
2.
Turn off the fuel valve.
3.
Allow the unit to stall out.
4.
Turn off the start switch.
5.
Add fuel stabilizer to the gas remaining in the tank.
6.
Store.
If you do not plan to
start the unit for
longer than 30 days.
1.
Turn off the main breaker.
2.
Allow the unit to run 3 - 5 minutes.
3.
Turn off the fuel valve.
4.
Allow the unit to stall out.
5.
Turn off the start switch.
6.
Drain the fuel tank (See “Emptying the Gas Tank” in the “Maintenance” section)
7.
Drain the carburetor
a.
Remove the drain bolt from the carburetor.
b.
Drain the small amount of remaining fuel from the carburetor bowl.
8.
Oil the cylinder
a.
Remove the spark plug.
b.
Put 2 tbsp. of 10w30 motor oil directly into the spark plug hole
c.
Pull the recoil start one time.
d.
Replace the plug.
9.
Remove the battery and place on tender indoors.
48
When transporting your generator:
●
Disconnect the spark plug.
●
Do not obstruct any ventilation openings & keep the generator in a cool dry area.
CAUTION
: Never place any type of storage cover on the generator while it is still
hot.
MAINTENANCE AND CARE (CONTINUED)
Storage and Transportation
Summary of Contents for XP2300IH
Page 2: ......
Page 5: ......
Page 12: ......
Page 41: ...MAINTENANCE LOG Date Generator Hours Maintenance Performed 41 ...
Page 50: ...50 ...
Page 53: ...53 ...
Page 59: ......
Page 60: ...5800 Ontario Mills Parkway Ontario CA 91764 United States 844 DuroMax REV XP2300iH 02032021 ...