Changing / Inspecting the Carbon Brushes
The carbon brushes in conjunction with the AVR regulates
power from the generator. The carbon brushes are wearable
parts and should be inspected every 250 running hours.
Remove generator cover
Remove bolt from brush
Disconnect AVR wires
Remove the 2 bolts of the generator cover then pull the cover
off the generator.
Remove the bolt holding the carbon brush.
Remove the two wires from the AVR on the carbon brush
1.
2.
3.
61
Summary of Contents for XP85000E
Page 2: ......
Page 5: ......
Page 20: ...20 ...
Page 28: ...28 ...
Page 36: ...36 ...
Page 44: ...44 ...
Page 47: ...MAINTENANCE LOG Date Generator Hours Maintenance Performed 47 ...
Page 66: ...WIRING DIAGRAM 66 ...
Page 67: ...67 ...
Page 73: ......
Page 74: ...5800 Ontario Mills Parkway Ontario CA 91764 United States 844 DUROMAX REV XP8500E 07072020 ...