Operation
How to use the RAC IV tip guard.
WARNING
INJECTION HAZARD
To reduce the risk of serious injury,
whenever you are instructed to relieve
pressure, follow the Pressure Relief
Procedure on page 9.
The tip guard alerts you to the risk and helps prevent
placing any part of the body close to the spray tip. The
tip guard also adjusts the vertical or horizontal spray
pattern. See Fig. 8. The tip guard holds a reversing
spray tip. The tip is in the spraying position when the
tip handle points forward. See Fig. 6.
Clean the front of the tip frequently during the day’s
operation. First, follow the Pressure Relief Procedure
on page 9.
Fig. 6
Tip handle shown in
spraying position.
Turn handle 180
,
trigger gun to clear clog
1
2
2
1
04647
How to remove a tip clog.
1.
Release the gun trigger. Lock the safety latch. Ro-
tate the RAC IV tip handle 180
. See Fig. 6.
2.
Unlock the safety latch. Trigger the gun into a pail
or onto the ground to remove the clog.
3.
Lock the safety latch. Rotate the tip handle to the
spraying position.
4.
If the tip is still clogged, lock the safety latch, shut
off and unplug the sprayer, and open the pressure
drain valve to relieve pressure. Clean the spray tip
as shown in manual 307–848, supplied.