Step 3 - Connect the Battery
22
GENERATOR SETUP (CONTINUED)
Disconnected on arrival
1.
Cover the terminal
a.
Cover the connected terminal with the black rubber
boot.
4.
Locate the negative cable
a.
Locate the negative battery cable above and behind
the battery. One side is connected to ground and
the other end needs to be connected to the battery.
b.
Route the free end to the negative battery terminal.
2.
Connect the negative cable
a.
Push the black rubber boot up the wire to eDSose
the connector.
b.
Securely connect the free end of the battery cable
to the negative battery terminal using the screw
and nut from the battery with the screwdriver and
wrench from the toolkit.
3.
The generator battery is disconnected on arrival to prevent
discharge or accidental starting in storage and transportation.