25
• Drain off condensation water
from tank at least once a month.
This should be done once a day
in areas where a high degree of
humidity prevails or in tropical
countries.
Refer to Section 12.3
"Draining off Condensation
Water".
Carefully observe ambient
temperature of compressor.
Refer to Section 8.1
"Environmental Conditions".
• Remove screws (63) from control
unit and clean control nozzles
using cleaning pin (60).
• Replace control unit.
For maintenance work or in the
event of defects occurring, the
control unit (64) can be
dismantled on the dry-air system.
– Dismantle dry-air system on
compressor.
– Remove three hexagon socket
screws (65) from base of dry-air
system.
– Remove control unit (64).
– Remove O-rings (62) from base
of water collecting chamber and
replace by new ones.
– Remove valve together with
sealing washer and compression
spring (61) and substitute by
supplied parts.
6. Water is dripping
out of the air
consumers
(e.g., turbine).
7. Compressor is
running and
compressed air is
being blown off
via the dry-air
system.
• Condensation water in tank.
• Congestion of control nozzle on
dry-air system.
• Control unit defective.
Possible Cause
Fault
Removal of Fault
25
60
63
60
63
64
65
61
62