10
1036100102L02 1904V002
Product description
4.3 H2A-160M, article 1036100620
Electrical data
1036100620
Nominal voltage
V
230 / 1~
Electrical frequency
Hz
50
60
Nominal current at 8 bar (0.8 MPa)
A
12.2
14.3
Motor protection switch, recommended
setting
A
6.5
7.6
Speed
min
-1
1410
1690
Type of protection
IP 24
Mains fusing *
A
20
*
Circuit breaker fuse characteristics B, C or D in acc. with EN 60898-1
General technical data
Pressure vessel volume
L
50
Suction power, approx.
l/min
420
505
Delivery at 5 bar (0.5 MPa)
l/min
230
260
Pressure build-up phase 0 - 7.5 bar (0 -
0.75 MPa) approx.
s
115
100
Duty cycle
%
100
Switch-on pressure
bar (MPa)
6 (0.6)
Cut off pressure
bar (MPa)
7.8 (0.78)
Cut off pressure, max. adjustable
bar (MPa)
9.5 (0.95)
Safety valve, maximum permissible oper-
ating pressure
bar (MPa)
10 (1)
Pressure dew point at 7 bar (0.7 MPa) *
°C
≤
+5
Dimensions (H x W x T) ***
cm
76 x 79 x 52
Weight
kg
90
Noise level ****
without sound insulation
with sound insulation
dB(A)
dB(A)
69
55
74
56
*
Value determined at an ambient temperature of +40 °C
** With ORANGE rinsing nozzle
*** Values without accessories and add-on parts
**** Noise level in accordance with EN ISO 1680 "Airborne noise emissions"; measured in a room
with sound damping. The levels are average values with a tolerance of ± 1.5 dB(A). Higher val-
ues may be obtained in rooms with reverberating sound characteristics.
Filter mesh size
Compressor air intake filter
µm
3
Fine filter cartridge 3 µm for mem-
brane-drying unit
µm
3
Fine filter cartridge 0.01 µm for mem-
brane-drying unit
µm
0.01
Sintered filter for membrane drying unit
µm
35
EN
Summary of Contents for H2A-160M
Page 2: ......