12
1036100102L02 1904V002
Product description
4.4 P2B-304M, article 1036100630
Electrical data
1036100630
Nominal voltage
V
230 / 3~
Electrical frequency
Hz
50
60
Nominal current at 8 bar (0.8 MPa)
A
15.2
16.6
Motor protection switch, recommended
setting
A
9
9
Speed
min
-1
1440
1700
Type of protection
IP 24
Mains fusing *
A
20
Max. permissible mains impedance in
acc. with EN 61000-3-11 **
W
≤
0.445
*
Circuit breaker fuse characteristics B, C or D in acc. with EN 60898-1
** Mains impedance at 6 switching cycles per hour. If the number of switching cycles per hour is
higher, a lower mains impedance is required.
General technical data
Pressure vessel volume
L
90
Suction power, approx.
l/min
845
1010
Delivery at 5 bar (0.5 MPa)
l/min
430
480
Pressure build-up phase 0 - 7.5 bar (0 -
0.75 MPa) approx.
s
90
80
Duty cycle
%
100
Switch-on pressure
bar (MPa)
6.5 (0.65)
Cut off pressure
bar (MPa)
8.5 (0.85)
Cut off pressure, max. adjustable
bar (MPa)
9.5 (0.95)
Safety valve, maximum permissible oper-
ating pressure
bar (MPa)
10 (1)
Pressure dew point at 7 bar (0.7 MPa) *
°C
≤
+5
Dimensions (H x W x T) **
cm
76 x 102 x 62
Weight
kg
143
Noise level ***
dB(A)
69
74
*
Value determined at an ambient temperature of +40 °C
** Values without accessories and add-on parts
*** Noise level in accordance with EN ISO 1680 "Airborne noise emissions"; measured in a room
with sound damping. The levels are average values with a tolerance of ± 1.5 dB(A). Higher val-
ues may be obtained in rooms with reverberating sound characteristics.
Filter mesh size
Compressor air intake filter
µm
3
Fine filter cartridge 3 µm for mem-
brane-drying unit
µm
3
Fine filter cartridge 0.01 µm for mem-
brane-drying unit
µm
0.01
Sintered filter for membrane drying unit
µm
35
EN