Assembly
8.5 Draining the condensation wa-
ter
Units without a membrane-drying unit
When air from the surrounding atmosphere is
compressed, different amounts of condensate
will accumulate in the pressure vessel depend-
ing on the humidity and temperature of the air.
The condensate must be let off in regular inter-
vals:
i
Place a collector tray under the condensate
drain.
i
Open the condensate drain valve at maximum
tank pressure.
i
Close the condensate drain valve as soon as
all of the condensate has been blown out.
connector. Close the lock on the connector
housing.
3
4
3 Lock
4 Pin connector housing
8.4 Pressure reducer (optional)
i
Insert the pressure reducer into the quick re-
lease coupling.
i
Insert the pressure hose into the quick release
coupling on the pressure reducer.