34
1036100102L02 1904V002
Usage
12.4 Taking out of use
If the unit is not to be used for a prolonged peri-
od of time, we recommend that it is properly
shut down and taken out of use.
To do this, the accumulated condensation water
from the unit must be drained.
i
Switch on the unit and wait until the cut-off
pressure is reached.
Pressure tank
i
Switch off the unit.
i
Disconnect the mains plug.
i
Relieve the full pressure from the compressed
air vessel (e.g. using a blow-off gun connect-
ed to the quick-release coupling or via the
condensate drain valve (if present)).
i
Disconnect the compressed air connection on
the quick release coupling.
Storage of the unit
WARNING
Risk of explosion of the pressure
tank and pressure hoses
i
The pressure tank and the pressure
hoses must be vented before they are
stored or transported.
i
Protect the unit against moisture, dirt and ex-
treme temperatures during transport (refer to
the section on "Ambient conditions").
i
Only store the unit when it has been com-
pletely emptied.
Sintered filter
i
Unscrew and remove the filter housing.
i
Remove the sintered filter.
i
Insert a new sintered filter.
i
Replace the filter housing and close.
EN
Summary of Contents for H2A-160M
Page 2: ......