DANGER
The temperature switch may suffer
damage from a motor lockage or a
short circuit in the motor winding
Insufficient fuse protection of the electric
motors can result in fire, electric shock,
personal injury or material damage.
❯
Installation of a circuit breaker.
DANGER
Insufficient fuse protection of the
electric motors in unmonitored instal-
lations
Insufficient fuse protection of the electric
motors can result in fire, electric shock,
personal injury or material damage.
❯
Installation of a circuit breaker.
❯
The temperature switch must be con-
nected to a suitable relay.
7
Commissioning
7.1
Remove the transport locks
The unit is securely protected with packaging
material to ensure safe transportation.
❯
Remove the packaging material.
❯
Remove the protective film.
❯
Check the unit for damage in transit.
7.2
Connect oil-free piston com-
pressor
Depending on the product, the units are
designed for a specific nominal pressure
(see "4.2 Technical data").
If this nominal pressure is exceeded, the
service life of the product is reduced.
The connections for the air inlet and air outlet are
located on the cylinder head. The atmospheric air
is drawn in via the air intake filter on the air inlet
side. On the air outlet side, the compressed air
flows through the air line to the consumer.
Air inlet
The air inlet opening is located on the cylinder
head. A suitable air intake filter must be mounted
on the air intake filter to preserve the service life
of the unit.
❯
The units are supplied with matching air intake
filters.
Air outlet
The air outlet opening is located on the T-piece
between the cylinder heads.
❯
Connect a pressure hose to the external thread
M16 x 1.5.
Operating the unit in a system
If the unit is installed in a system, the safety pres-
sure must not be exceeded (see "4 Technical
data"). Ensure that the safety pressure does not
exceed permissible overpressure values by pro-
viding of a safety device (e.g. safety valve,
solenoid valve etc.).
The operating or working pressure may not
exceed the nominal pressure of the unit. Acces-
sories for pressure control, e.g. pressure
switches and pressure reducers, are necessary in
order to ensure a constant mains pressure during
operation.
Depending on the application, control systems,
valve units, containers or other accessories are
required for safe operation.
Assembly
22
1035200220L02 1911V002
EN