0678106030L02 1411V002
75
Mounting
(+) (-)VDC
-X1
30
87
85
86
-K
DC
M
PE
-M
P>
3 1
4 2
-Q
Figure 42: Installation of a compressor unit with DC permanent-magnet motor in a compressor
station - connection of pressure switch with indirect wiring via relay (for high currents)
-X1 Mains connection
-Q Pressure switch
-K Relay
-M Compressor motor