2.2
Intended Use
The spray gun
Eco
Gun 910 is used exclu-
sively for spraying water-based paint and
conventional solvent-based paint. It is hand
guided and uses compressed air.
The
Eco
Gun 910 spray gun may only be
operated in the approved EX-zones and
within the approved technical data
Eco
Gun 910 spray gun is only intended
for use in application stations.
Misuse
There is a risk of death if not used properly.
Misuses include, e. g.:
Aiming the spray gun at humans or ani-
mals.
Atomization of fluid nitrogen
Combination of the spray gun with com-
ponents that are not approved by
Dürr Systems for operation.
Use of unapproved materials, see safety
data sheets
Making conversions or changes on your
own
Use of spray guns not conforming to the
device category in Ex zones.
EX labeling
II 2G T60 °C X
II
- Device group II: all areas except
mining
2G
- Device category 2 for gas
T60 °C - Surface temperature, max. 60 °C
X
- Specific operating conditions for
safe operation
The following conditions must be observed
for safe operation:
Ground the spray gun.
Only use conductive hoses.
Ensure that static electricity can be dis-
charged.
Use exclusively compressed air quick
couplings for water-based materials,
where it is not necessary to keep dis-
charging static electrical charges.
2.3
Residual risks
Explosion
Sparks, open flames and hot surfaces can
cause explosions in explosive atmospheres.
Serious injuries and death can be the conse-
quence.
Before carrying out any work, ensure a
non-explosive atmosphere.
Do not use sources of ignition and open
light.
Do not smoke.
Ground the product.
Ground the work piece.
Only use conductive lines.
Flammable coating materials and their deter-
gents and cleaning agents can cause a fire
or an explosion.
Ensure that the flashpoint of the fluid is at
least 15 K above the ambient tempera-
ture.
Note explosion group of the fluid.
Follow safety data sheets.
Ensure that forced ventilation and fire
protection equipment are in operation.
Do not use any sources of ignition and
open light.
Do not smoke.
Danger from harmful or irritant sub-
stances
Contact with hazardous liquids or vapors,
can result in serious injury or death.
Ensure that the forced ventilation is
operational.
Follow safety data sheets.
Wear specified protective equipment.
Escaping material
Material escaping under pressure can cause
serious injuries.
Safety
05/2018
EcoGun 910 - MSG00003EN
5/32