7.2
Cleaning
Personnel:
Operator
+ additional qualification explosion pro-
tection
Protective equipment:
Protective gloves
Safety boots
Protective workwear
Eye protection
Respiratory protection device
Use ear protection
1. Disconnect the air hose from the spray
gun.
2. Ensure the ambient temperature is at
least 15 K below the flashpoint of the
cleaning agent.
3. Remove material residue with cloth or
soft brushes.
4. Clean the spray gun carefully and dry it
with a soft cloth.
7.3
Maintenance
7.3.1 Maintenance schedule
The maintenance intervals given below are based on experiential values. Adjust maintenance
intervals individually if necessary.
Interval
Maintenance work
after each use
Cleaning
weekly
Lubricate needle guide
7.3.2 Lubrication
1. Lubricate the following parts with a sili-
cone-free grease:
O-rings
Needle guide
Needle seal
Lever bearing
Cleaning and maintenance
05/2018
EcoGun 910 - MSG00003EN
15/32