Operating Manual
© Dürr Systems GmbH
EcoGun AA MAN 2 P
Chyba! Pomocí karty Domů použijte u textu, který se má zde
zobrazit, styl Überschrift 1.
Version: 01
as of: 09/2014
18 / 46
For pressures in between 80 and 250 bar
choose
a
correspondingly
intermediate
adjustment of the screw Ref.1236-5.
6.7
Round jet regulation
With the round jet regulation Ref.1240-U5
atomization air is added to the flat jet cap.
Clockwise rotation - less air
-little
adjustment to round jet.
Counter clockwise rotation - more air
-high adjustment to round
jet.
6.8
Adjustment of atomization air cap
Put pump pressure at
0
, release trigger
Ref.1248-U4 completely - pressure of hose
relieves.
b.)
Secure spray gun by a 90 ° clockwise
rotation of the safety lever Ref.1237-3.
c.)
Release lock nut Ref.1248-4 by hand.
d.)
Put atomization cap Ref.1248-U2 into
required
position.
e.)
Tighten lock nut Ref.1248-4 by hand.
The position of the atomization air cap and the
spraying nozzle determines the direction of the
spray jet.
Turn the atomization cap according to the desired spray
direction -the spraying nozzle turns with it).