BIO-FIGHTER® ULTRA-FLEX INSTALLATION & OPERATION MANUAL

2

Dimensions

Chassis: 9.25"L x 4"W x 2 "H
Lamp Housing: 3.6"L x 3"W x 1.25"H
Lamp Bracket: 3.25"L x 3"W x 4"H

Weight:

Approx. 4 lbs.

Electrical

:

120V-240V, 50/60Hz, 1PH. 3 amp-250V fuse. 
6 ft. power cord.

U.S. Patent Nos. 5,334,347, 5,817,276, 6,245,293, 6,267,924,

 

6,280,686, 6,313,470, 6,627,000, 6,539,727, 6,932,494, 6,550,257.

Specifications subject to change without notice.

UV-C Light May Degrade Plastic and Rubber.

Shield exposed plastic drain pans, wire insula-
tion, flex duct, or other plastic/rubber compo-
nents from UV-C light. 

REMOTE LAMP MOUNTING LOCATION

Select a mounting location with enough clear-
ance for the lamp to be installed and replaced
easily. Allow a 1" clearance between duct sur-
face and lamp tip. 
A 120V or 240V electrical supply is required. 

CAUTION

Special Installation Notes

• Do not install in closet return grille applications.
• Do not install in outdoor applications.
• Do not expose wiring or plastic parts to UV-C light.
• Do not install where UV-C light can be seen

after installation.

• Do not install beneath a humidifier.
• If the UV device is installed on the inlet side

(return air side) of a coil, make sure that the

HVAC system is configured such that the

blower is located between the return air filter

and the inlet side (return air side) of the coil,

such as would be found in a traditional up-

flow, or horizontal furnace with the coil

placed after the heat exchanger.

• If the UV device is installed near an air filter,

check with filter manufacturer for UV-C

resistance properties.

• If the desired UV installation location is

intended to irradiate an air filter, to neutralize

the microbiological matter on the air filter

surface, such as would be found in the

return air drop of a basement application or

in the return plenum of a horizontal system

in an attic; take precautions as described in

note above, and make sure the UV fixture is

placed on the return side of the filter. DO

NOT INSTALL THE UV FIXTURE ON EITHER

SIDE OF THE FILTER IN HALL / CLOSET

RETURN AIR APPLICATIONS. 

(See ATTEN-

TION! Warning sheet #212945-00).

250V/3 Amp Fuse Only

ON

OFF

9.25"

2"

4"

Remote Lamp Housing

3.6"

1.25"

3"

ETL LISTED
CONFORMS TO
UL STD 1598 
CERTIFIED TO
CSA STD C22.2 NO. 250.0

2002554

EPA Device Manufacturer Establishment No. 73316-TX-1

The product and technologies described are not medical devices, and are 
not intended to diagnose, treat, cure, or prevent any disease or illness.

Summary of Contents for BIO-FIGHTER Ultra-Flex 1S

Page 1: ...yeast and molds This process either destroys the microorganism or neutralizes its ability to reproduce FEATURES Reduces or prevents mold growth on HVAC coils allowing them to operate at peak efficien...

Page 2: ...d on the inlet side return air side of a coil make sure that the HVAC system is configured such that the blower is located between the return air filter and the inlet side return air side of the coil...

Page 3: ...mote lamp base to the surface with the included mounting screws Using the remote lamp base as a template drill a 1 hole for the lamp Fig 2 Lamp is secured with a sliding bracket tightened with two knu...

Page 4: ...ig 5 Attach the connector to the lamp Hold back the protective boot to expose the harness connector The harness connector is asymmetrical and can only be attached one way If the harness does not attac...

Page 5: ...duct Then press the viewport into the hole Connect green wire to ground Power Cord Connect black and white wires to 120V 240V power Fig 8 Power cord connection FUSE REPLACEMENT 1 Turn off power to the...

Page 6: ...aching the lamp harness Not required for internal lamp mount option 10 Reconnect lamp harness 11 Reconnect power 12 Verify operation using viewport Burn Hazard During replacement allow lamps to cool 1...

Page 7: ...DUST FREE LP EXPRESSLY DISCLAIMS ALL OTHER WARRANTIES WHETHER WRITTEN OR ORAL IMPLIED OR STATUTORY INCLUDING BUT NOT LIMITED TO ANY WARRANTIES OF MERCHANTABILITY WORKMAN SHIP OR FITNESS FOR A PARTICU...

Reviews: