background image

ENGLISH

  Grounding 

Instructions

 

 

This air mover must be grounded while in use to protect the operator from electric shock. This machine is built    

 

 

with a 3-wire cord and a 3-prong grounding-type plug (Figure 1) to fit a properly grounded receptacle.

Before using this machine, make sure a properly grounded, 3-hole electrical outlet is available. Never assume that all 3-hole outlets 

are properly grounded. Check before use. 

Correct a faulty grounding before proceeding.

EXTENSION CORDS ARE NOT RECOMMENDED

The air mover is built with a 20-foot, 16/3-gauge safety power cord. Use of any extension cords is NEVER RECOMMENDED.

 

Operating Tips

 

• For indoor use only.

 

• Adjust the air mover to the desired position for operation by tipping the machine onto one of the three flat faces of the    

 

   heavy-duty plastic chassis. The balanced machine design assures stable positioning.

 

• Plug the power cord into a grounded outlet.

 

• This air mover has three (3) power settings controlled at the side of the machine. Turn the power knob on the side of the   

 

   air mover to the desired speed.

 

• 1 = 780 RPM, 2 = 1000 RPM, 3 = 1500 RPM. To turn the air mover off, turn the power knob to the off position.

 

• Never pull on the cord to disconnect or turn off the motor.

Storing the Air Mover

 

• Wind the cord around the carrying handle.

 

• Store in the upright position in a dry area.

 

• Check and clean after each operation. Remove soil and chemical buildup. Use vacuum and soft brush to remove soils from  

 

  motor vents and fan blades.

 

• Wipe the outside chassis with a mild cleaner. Never wash the outside of the air mover with flowing water. Make sure that 

 

  the air intakes are not blocked.

 

• Check switches for proper operation. Call a trained electrician to repair or replace damaged cords and plugs.

 

• Report problems and repair promptly.

  Troubleshooting 

Guide

 

 

Never operate this air mover when the equipment is not performing as expected or when any part is visibly  

 

 

 

damaged. When repair is needed, take the equipment to an authorized service center.

Air Mover will not run

 

• Circuit breaker tripped in building. Check and reset.

 

• Equipment unplugged. Check plug at wall and plug in.

 

• Power cord failure. Seek authorized repair services.

 

• Motor sparks or smokes. Seek authorized repair services.

High vibration

 

• Air Mover fan blades are damaged or broken. Seek authorized repair services.

 

• Motor bearings are worn. Unplug the air mover and spin the fan blades. If the spinning causes noise or restricted  

 

 

  movement, replace the air mover with new equipment.

Summary of Contents for 19669

Page 1: ...s Manual Manuel de pièces et d opérations Air Mover Code 19669 Serial Number Numéro de série ______________________ Date of Purchase Date d achat _________________________ More info Plus d info www dustbane ca 2015 03 ...

Page 2: ...nding instructions for more details This air mover is designed for commercial use It is constructed for indoor use and its not intended for any other use DO NOT use in flammable or explosive areas Never operate this air mover near flammable or explosive dusts liquids or vapors DO NOT use with damaged cord or plug DO NOT use outdoors Do not expose to rain DO NOT use in standing water DO NOT use air...

Page 3: ... to the off position Never pull on the cord to disconnect or turn off the motor Storing the Air Mover Wind the cord around the carrying handle Store in the upright position in a dry area Check and clean after each operation Remove soil and chemical buildup Use vacuum and soft brush to remove soils from motor vents and fan blades Wipe the outside chassis with a mild cleaner Never wash the outside o...

Page 4: ...Parts Pièces 3B 11 12 9B 19669 Air Mover ...

Page 5: ...red 1 5 S90 1027 Switch Housing 1 5A S10 0608 Warning Label 1 5B S10 0050 B Switch Screw 1 5C S90 1024 Switch Washer 1 6 S10 0448 20 ft Cord 1 7 S10 0604 Wire Finger Guard 1 8 S10 0615 Screws for Wire Guard 6 9 S90 1010 Rivet for Screen 8 9B S90 1024 Washer for Screen 10 S10 0603 Intake Screen with Ring 1 11 S90 1026 Venturi Ring 1 12 S10 0605 Main Body 1 S90 1025 Rubber Feet Not Pictured 2 S10 06...

Page 6: ...r le cordon Ne pas étirer le cordon NE PAS manipuler la fiche avec les mains mouillées Gardez les cordons des surfaces chaudes Ne permetter pas à la prise d air de collecter les débris enflammés ou fumants comme des cigarettes des allumettes ou des cendres chaudes NE PAS déplacer l air avec des produits chimiques inflammables ou explosifs Gardez la prise d air exempt de débris Ne pas utiliser avec...

Page 7: ...z le châssis extérieur avec un détergent doux Ne jamais laver l extérieur de l appareil de ventilation avec de l eau qui coule Vérifier les prises d air ne sont pas bloquées Vérifiez les interrupteurs pour un fonctionnement correct Appeler un électricien qualifié pour réparer ou remplacer les cordons et les bouchons endommagés Aviser votre superviseur de tout problèmes répararer rapidement Guide d...

Page 8: ......

Reviews: