DC 2800c, 12
Art nr 9453
Problem
Fault
Solution
Motor will not start.
Machine not connected.
Make sure connection.
The motor stops directly
Incorrect fuse.
Change to correct circuit.
after starting.
Fan runs but no suction.
Hose not connected.
Connect the hose.
Hose plugged.
Find and remove block.
No plastic sack on the
Mount the correct sack.
cyclone.
Fan runs but poor suction.
Hole in the hose.
Change or repair hose.
Plugged filter.
Clean or change filter.
Hose too long or too small.
Change the hose.
Hose is kinked.
Check and free.
Machine top is mounted
Adjust the mounting.
incorrectly.
Dust is packed in the
Take off the top and clean
cyclone.
out.
Machine blows dust.
Filter is perforated or has
Check the filters and change
come loose.
if necessary.
Abnormal sound from
Order service.
machine.
TROUBLE SHOOTING
Warranty
The warranty period for this machine is two years
and covers manufacturers faults. The warranty is valid
under the condition that the machine is used under
normal conditions on the task for which it was desig-
ned and is maintained properly.
Normal wear is not covered by this warranty. Ser-
vice performed by other than Dustcontrol or its autho-
rized agent voids automatically the warranty. No other
warranty express or implied is applicable.
Description
Part no
Plastic sack, standard
4713
Fine filter, cellulosa with
integrated filter cover
42029
Fine filter, polyester with
integrated filter cover
42028
Microfilter
42027
Other accessories, see Dustcontrol
catalogue.
Accessories