background image

 

Hangzhou Roombanker Technology Co., Ltd.

                     

                            A DUSUN company

 

Hangzhou Roombanker Technology Co., Ltd.             Floor 8, building A, Wantong center,  
Tel:86-571-86769027/8  8810480                       Hangzhou 310004, china 
Website: www.dusuniot.com     www.dusunremotes.com   www.dusunlock.com 

Note

5VDC from type C USB; 5~12VDC from intercom connection Port 

5.3

 

TX power consumption during constant emission 

Working 

status 

Rate 

Tx Power/receiver 

Average Value 

Maximum Value 

Unit 

Tx 

250Kbps 

+20dbm 

200 

206 

mA 

Tx 

250Kbps 

+10dbm 

62 

64 

mA 

Tx 

250Kbps 

0dbm 

26 

28 

mA 

Rx 

250Kbps 

Constant receiving 

10 

12 

mA 

Rx 

250Kbps 

Constant receiving 

10 

12 

mA 

RX 

250Kbps 

Constant receiving 

10 

12 

mA 

5.4

 

working current 

Working Mode

 

Working status

Ta=25℃ 

Average value 

Maximum value 

unit 

EZ mode

 

The product is in EZ mode.

 

10 

40 

mA 

Connected and idle

 

The product is connected to the network

 

14.2 

15 

mA 

Deep sleep mode

 

The product in deep sleep mode,

 

50 

uA 

 

6

 

Zigbee RF features 

6.1

 

Zigbee Basic RF features 

Parameter 

Description 

Frequency band 

2.405~2.480GHz 

Wireless standard 

IEEE 802.15.4 

Data transmission rate 

250Kbps 

Antenna type 

PCB antenna with a gain of 1.8dBi, option Ipex 

6.2

 

Zigbee Tx performance 

Performance during constant transmission

 

Parameter 

Min. 

Typ. 

Max. 

unit 

Maximum output power(250Kbps)

 

20 

dBm 

Minimum output power(250Kbps)

 

-30 

dBm 

Output power adjustment step

 

0.5 

dBm 

Output spectrum adjacent-channel rejection ratio 

-31 

dBc 

Frequency error 

-15 

15 

ppm 

6.3

 

Zigbee Rx performance 

Rx sensitivity 

Parameter 

Min. 

Typ. 

Max. 

unit 

PER<8%

RX sensitivity(250Kbps) 

-102 

-101 

-99 

dBm 

 

7

 

BT/BLE performance 

7.1

 

Transmitter

BLE

 

Parameters

 

min

 

Typ

 

max

 

Unit

 

Transmit power

 

dBm 

Summary of Contents for DSW-080

Page 1: ...center Tel 86 571 86769027 8 8810480 Hangzhou 310004 china Website www dusuniot com www dusunremotes com www dusunlock com User Manual Product Name Smart Switch Model Name DSW 080 Revision History Specification Sect Update Description By Rev Date 1 0 2022 05 20 New version release Approvals Organization Name Title Date ...

Page 2: ...tton function 7 4 6 Power on default state setting 7 4 7 Configurable reporting time 7 4 8 OTA function 7 4 9 Voltage detection 7 5 Electrical Characteristics 7 5 1 Absolute Electrical 7 5 2 Normal electrical conditions 7 5 3 TX power consumption during constant emission 8 5 4 working current 8 6 Zigbee RF features 8 6 1 Zigbee Basic RF features 8 6 2 Zigbee Tx performance 8 6 3 Zigbee Rx performa...

Page 3: ...k com 11 Reference application 11 11 1 Garden Door control 11 11 2 Garage Door control 11 11 3 Intercom control 12 11 4 Door access control 15 11 5 Thermostat control 15 12 Installation 15 12 1 3M adhesive stickers 15 12 2 Fixing with expansion screw 16 12 3 Extension of the antenna 16 13 Certification 17 14 Marking packaging transportation and storage 17 14 1 Logo 17 14 2 Packaging 17 14 3 Transp...

Page 4: ...rrent 100uA Average working current 45mA Support Bluetooth 5 2 with external antenna Support Zigbee3 0 can connect to gateway Support DC power supply and Li battery backup 2 channel Relay switch for access control garage door control and 2 sensor input I O for status detect 2 ports for electric accessories UART or RS485 Modbus Operation temperature 10 55 Operation humidly 90 NON condition Button 2...

Page 5: ...mpany Hangzhou Roombanker Technology Co Ltd Floor 8 building A Wantong center Tel 86 571 86769027 8 8810480 Hangzhou 310004 china Website www dusuniot com www dusunremotes com www dusunlock com 1 4 Hardware block 2 Mechanical Requirement 2 1 Drawings ...

Page 6: ...nds Device is working normally green Slow flashing 3 times Restore factory Slow flashing Pair mode Red Slow flashing Low voltage Fast flashing Shut down Always on Network failure Note When the indicator and status lights are working the power indicator does not work Short press key time 200mS 4 2 Power on initialization When the product is powered on the Blue indicator flashes slowly for 2 times a...

Page 7: ...t by users according to their own needs ranging from 1 64800 seconds and the default is 60 seconds 4 8 OTA function The device supports the OTA function and the device can be upgraded remotely through the gateway The OTA function requires a digital signature function and programs other than the device cannot be upgraded 4 9 Voltage detection The product has a built in lithium battery When the exte...

Page 8: ...ximum value unit EZ mode The product is in EZ mode 10 40 mA Connected and idle The product is connected to the network 14 2 15 mA Deep sleep mode The product in deep sleep mode 50 uA 6 Zigbee RF features 6 1 Zigbee Basic RF features Parameter Description Frequency band 2 405 2 480GHz Wireless standard IEEE 802 15 4 Data transmission rate 250Kbps Antenna type PCB antenna with a gain of 1 8dBi optio...

Page 9: ...ing 30MHz 2000MHz 30 dBm 2003MHz 2399MHz 35 dBm 2484MHz 3000MHz 35 dBm 3000MHz 12 5GHz 30 dBm Intermodulation 71 dBm 8 Interface 8 1 RS 485 The interface of the product as below J1 and J2 is for the control for access control Pin No J1 J2 1 B B 2 A A 3 GND GND 4 VCC VCC 8 2 RS 232 The interface of the product as below J1 and J2 is for the control for access control The baud rate is 2400 38400bps t...

Page 10: ...e humidity 90 3 48h working Salt spray Concentration of salt solution 5 0 1 Temperature 35 2 Mist absorption time 15 minutes spray every 45 minutes Salt fog precipitation 1 0mL h 80cm 2 0ml h 80cm 48h Non wor king 9 2 Mechanical adaptability Carry out the mechanical environment adaptability test on the product according to the following table and it should work normally after the test The mechanic...

Page 11: ...ctric garden door open Option Mobile phone with app can scan the Bluetooth signal in the near the DSW 080 is always in activity status the app will be automatic connect the DSW 080 User can control the garage door by the mobile phone Remark After entering the administrator mode the mobile app can connect to DSW 080 via Bluetooth and DSW 080 will send the secret key to the mobile app DSW 080 will a...

Page 12: ...e app 11 3 Intercom control Can connect the phone to DSW 080 through a flat cable and then connect DSW 080 to the network to realize remote control of the phone and remote real time access to the status of the call DSW 080 can be set as a Zigbee router some Zigbee sensor and devices can connect to it Remark GND and SENSOR is for detect the action of bell ring NO and COM is used for open the door N...

Page 13: ...doorbell button is pressed the voltage differential varies markedly that is the sensor terminal Step 3 Find the COM and NO port Generally NO and COM are the two ends of the door open button Use the beep of the multimeter to find the terminal that is completely short circuited to the two ends of the door open button These two terminal can be used to connect the NO and COM ports of DSW 080 Remark If...

Page 14: ...se reduction microphone and speaker function supports USB audio protocol the connection diagram is as follows 1 Connect the output port Type C of the sound pickups to the power supply port of the smart switch 2 Connect the power supply port USB of the pickup to the 5VDC adapter for the power supply of the pickup and smart switch Note Install the sound pickups as close to the intercom as possible S...

Page 15: ...trator mode the mobile app can connect to DSW 080 via Bluetooth and DSW 080 will send the secret key to the mobile app DSW 080 will always be in the broadcasting state when it is not connected When the user holds the authorized mobile app close to it it will connect and exchange the secret key Whether to open the door automatically depends on the logic of the mobile app 11 5 Thermostat control Con...

Page 16: ... size M3 25 Quantity 4pcs Step1 Drill holes in the corresponding positions of the wall and plug the expansion cap into the hole punching positions of the wall Step2 Place the Cradle in the corresponding position and fix it with expansion screws Step3 Place the product into the cradle 12 3 Extension of the antenna The antenna can be replaced with an extendable antenna suitable for areas with poor R...

Page 17: ...standard number 14 2 Packaging 8 2 1 The packaging materials should be clean dry and acid alkaline should meet the packaging requirements of neutral materials 8 2 2 The product is equipped with the required accessories and is accompanied by product instructions and conformity marks 8 2 3 The outer packaging should have sufficient strength to ensure that the product is not damaged or scratched duri...

Page 18: ...ntial installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be det...

Reviews: