background image

 

 

 

Page 7 of 21 

 

 

Set the GMT time 

Press Button 8 (or “Display” key on IR handset) to select 

YY, MM, DD, hh, mm and ss.

 

Press Button 6 / 7 (or “+” / “-“ key on IR handset) to set the date and time.  
Press Button 8 (or “Display” key on IR handset) to select 

Save and Exit

 

Press Button 6 (or “-“ key on IR handset) to exit without save.  
Press Button 7 (or “+” key on IR handset) to save and exit.  
Reboot the unit.  
 

Important Note:

 The player was set to GMT=0 by default. If you have already set your local time zone 

in previous section (Change the Time Zone). Please skip this section or leave the clock to GMT setting. 

 

Set the OSD 

Press Button 8 (or “Display” key on IR handset) to select 

OSD

Press Button 6 / 7 (or “+” / “-“ key on IR handset) to set “ON” or “OFF”.  
Press Button 8 (or “Display” key on IR handset) to select 

Save and Exit

 

Press Button 6 (or “-“ key on IR handset) to exit without save.  
Press Button 7 (or “+” key on IR handset) to save and exit.  
Reboot the unit. 
 

Set the Datalog 

Press Button 8 (or “Display” key on IR handset) to select 

Datalog

Press Button 6 / 7 (or “+” / “-“ key on IR handset) to set “ON” or “OFF”. 
Press Button 8 (or “Display” key on IR handset) to select 

Save and Exit

 

Press Button 6 (or “-“ key on IR handset) to exit without save.  
Press Button 7 (or “+” key on IR handset) to save and exit.  
Reboot the unit. 
 

Set the System Message 

Press Button 8 (or “Display” key on IR handset) to select 

System Message

Press Button 6 / 7 (or “+” / “-“ key on IR handset) to set “ON” or “OFF”. 
Press Button 8 (or “Display” key on IR handset) to select 

Save and Exit

 

Press Button 6 (or “-“ key on IR handset) to exit without save.  
Press Button 7 (or “+” key on IR handset) to save and exit.  
Reboot the unit. 

Summary of Contents for ViewStream 500

Page 1: ...Manual ViewStream 500 Version 2 3 ...

Page 2: ...asic Setup Notes 4 2 2 Content update 8 2 3 Network Setup 8 2 4 Additional functions 12 3 Dimensions 14 4 Specifications 15 5 FAQ Frequently Asked Questions 17 6 Troubleshooting 19 Revision History Amendment Date Version June 2010 V1 0 August 2010 V2 0 June 2011 V2 1 August 2011 V2 2 July 2012 V2 3 ...

Page 3: ... 5 6 7 8 9 Item Description Type Use 1 DIP switch 8 pos Display output selection 2 Remote Ext 8 pin mini DIN socket for external button 3 RJ 45 LAN Network connection 4 HDMI DVI out HDMI connector 5 RS 232 port DB 9 M connector 6 Audio output Speaker out Stereo jack 3 5mm 7 Coaxial audio out RCA jack orange 8 S Video output Mini DIN 5 pin connector 9 Composite video output RCA jack yellow 10 VGA Y...

Page 4: ...he recommended brand is SanDisk all capacities and speeds should be suitable Other brands may also be acceptable CF cards should be formatted using FAT32 before first use All media files on the CF card must be in a folder name media All media filenames must be an alphanumeric character only not space _ etc The media filename must not exceed 16 3 format Note The DV Studio software will truncates th...

Page 5: ...creen display 1920x1080 o For output to a standard 4 3 display 1600x1200 DIP Switch settings 1 2 3 4 5 6 7 8 SW1 HDMI DVI 1920x1080p 60Hz HDMI DVI 1280x720p 60Hz HDMI DVI 1600x1200p 60Hz HDMI DVI 1024x768p 60Hz ON 1 2 3 4 5 6 7 8 SW1 ON 1 2 3 4 5 6 7 8 SW1 ON 1 2 3 4 5 6 7 8 SW1 ON 1 2 3 4 5 6 7 8 SW1 Component YPbPr 1920x1080i 60Hz Component YPbPr 1280x720p 60Hz Component YPbPr NTSC Component YPb...

Page 6: ...e you may need a 8 button keypad or touch screen or IR remote handset IR Remote handset Configuration Mode MAC 000562010406 Kernel Version V2 83 01 10 Version V1 08 10 RP 500 Volume 16 TZ 0 YY 09 MM 11 DD 19 hh 15 mm 54 ss 50 OSD ON Datalog ON System Message ON Save and Exit 8 key Button 7 8 1 8 segment Touch screen 2 3 4 5 6 To enter configuration mode holding Button 8 or Display key on IR handse...

Page 7: ...set ON or OFF Press Button 8 or Display key on IR handset to select Save and Exit Press Button 6 or key on IR handset to exit without save Press Button 7 or key on IR handset to save and exit Reboot the unit Set the Datalog Press Button 8 or Display key on IR handset to select Datalog Press Button 6 7 or key on IR handset to set ON or OFF Press Button 8 or Display key on IR handset to select Save ...

Page 8: ... FTP Pull mode The server can be a CMS Content Management Software server authorized by Digital View or any FTP based server If you already registered an A C through the CMS service provider Please refer to the procedure given by your CMS service provider To use with FTP Pull mode the pos 7 on DIP Switch must set to OFF up Using DV Studio to deploy content and files directly on to media player FTP...

Page 9: ...232 port 0 Disable message output 1 Enable message output Default IP_OVERWRITE Change IP settings on player 0 Keep the old IP settings on player Default 1 Overwrite with new IP settings on player IP IP address 0 0 0 0 DHCP mode Default 0 0 0 0 NETMASK Subnet mask Ignore if set to DHCP Default 0 0 0 0 GATEWAY Gateway value Ignore if set to DHCP Default 0 0 0 0 DNS1 DNS table DNS2 Default 0 0 0 0 TI...

Page 10: ... VGA 114 PAL S Video 4 1920x1080p60 VGA 201 1280x720p60 YUV 5 1024x768p60 VGA 212 1920x1080i60 YUV 6 800x600p60 VGA 213 NTSC YUV 7 640x480p60 VGA 214 PAL YUV 8 1920x1200p60 VGA 401 1280x720p60 HDMI 9 1600x900p60 VGA 404 1920x1080p60 HDMI 10 1600x900p60 VGA 405 1024x768p60 HDMI 11 1600x1200p60 VGA 411 1600x1200p60 HDMI NETWORK_NO Network type 0 RJ 45 cable Default 1 Wi Fi For E1 10 10h only WIRELES...

Page 11: ...enable 0 Disable 1 Enable Default FTP_UPDATE_ENABLE Enable DV Connect mode 0 Content pull mode Default 1 Content push mode DISPLAY_MARK_ENABLE Display Mark Control 0 Disable Default 1 Enable 232LIVE_CMD_ENABLE RS 232 Command Control 0 Disable Default 1 Enable DIP_SW_OVERRIDE Override DIP Switch SW 7 settings 0 Use DIP switch setting SW 7 Default 1 Use FTP_UPDATE_ENABLE setting ...

Page 12: ...egment touch panel or analog touch panel External buttons External buttons can be added for track selection Barcode scanner A product barcode scanner can be supported with up to 1 000 referenced images or videos Data capture Details of all interactions with the player such as via the motion sensor touch screen buttons or barcode scanner can be recorded and stored on the CF card for later retrieval...

Page 13: ...easy to use and setup on your FTP based server with the VS 500 media player An application note of media player to FTP server sync setup is available for download from www dvsignage com support home Customization DV Signage provides customization services Please contact your local office for enquires ...

Page 14: ... 21 3 Dimensions 1 5 10 6 11 15 1 5 9 6 SW1 REMOTE EXT LAN HDMI VGA YPbPr RS 232 COMPOSITE S VIDEO COAXIAL AUDIO OUT ON DC 12V 1 2 3 4 5 6 7 8 ON 148 mm 156 7 mm 217 mm 217 mm 2 2 mm 52 mm 6 5 mm CF CF Unit in mm ...

Page 15: ...480i 576i Adapter is required Audio out Phone jack Stereo Digital coaxial SPDIF HDMI Stereo External I O ports RS 232 9600 N 8 1 USB Data upload Infra red use with DV IR handset P N 559000104 3 Remote Ext External button connection RJ 45 port LEDs Power LED Green Network LED Green Real time clock Battery backup RTC Power requirement DC 12V input Power consumption 500mA 12V Environmental Operating ...

Page 16: ... MPEG 4 H 264 Typical filename extension ts MPEG 2 specifications Screen size recommended 16 9 screen e g 1280x720 1920x1080 Resolution 1920x1080 Encoding bit rate 12 15Mbit s Audio bit rate 224Kbit s 48kHz at 16bits sample rate Frame rate 25Hz 29 97Hz Codec MPEG 2 PS TS Typical filename extension ts JPEG specifications Optimal JPG resolution on selected output 16 9 Composite S video output 720x57...

Page 17: ...a HD Video setting preset Q A How do I get video and still images to play in a particular order Create a playlist to specify the playback order by using DV Studio which can be downloaded from http www digitalview com viewstream software php Q A What is DV Studio An authoring tool from Digital View for the creation of playlists and additional functions with the ViewStream 500 Q A How do I get the m...

Page 18: ...be seen Q A What Where the user related files should be located on VS 500 media players The following shows what and where certain user related files should be located on 500 Series media players Note not all files are required the point is that if these files are used this is where they should be located ON THE CF CARD Inside the MEDIA folder Outside the MEDIA folder directory All content ts jpg ...

Page 19: ...mend not using greater than 40Mb s bit rate CBR Constant Bit Rate on the ViewStream 500 A high speed CF card 100x or above is recommend if playback HD video If the video was encoded with VBR Variable Bit Rate make sure the peak of bit rate should not exceed 40Mb s Problem Check Correction Video is very blocky The SD video encoding settings are for a lower resolution DVD settings are recommended Or...

Page 20: ...liabilities on the part of the manufacturer for damages including but not limited to special indirect consequential damages arising out of or in connection with the use of or performance of the products CAUTION Whilst care has been taken to provide as much detail as possible for use of this product it cannot be relied upon as an exhaustive source of information This product is for use by suitably ...

Page 21: ...Sales info dvsignage com ASIA 16 th floor Millennium City 3 370 Kwun Tong Road Kwun Tong Hong Kong Tel 852 2861 3615 Fax 852 2520 2987 Sales hk dvsignage com www dvsignage com All rights reserved The concepts designs specifications and commands presented in this document are proprietary to DV Signage and are only made available for use with DV Signage products Specifications subject to change with...