Preventative Maintenance Schedule
Noted below and to follow are general maintenance guidelines which must be followed and documented, this in
accordance with the DV Warranty. It is based on an approximate Compressor usage of 40 hours per week. If your
particular application varies from this, please adjust accordingly.
N
o
te
s
D
a
ily
W
e
ek
ly
M
o
nt
h
ly
E
ve
ry
3
M
o
n
th
s
E
ve
ry
6
M
o
n
th
s
E
ve
ry
Y
e
ar
Normal Maintenance
Drain moisture from Air Receiver
Check oil level and top up as required
Replace Air Filter
1
Replace Oil (mineral)
2
Check condition/alignment of Belts/Pulley
3
Check Safety Valves
Check that Unit unloads when shutting down
Clean and/or blow dust/dirt off Unit
Inspect Check Valve
Inspect Pressure Gauge
Notes:
1. Air Filters are available separately or in the Maintenance Kit. Consult the Pump breakdown.
2. Mineral Oil is available separately or in the Maintenance Kit. Consult the Pump breakdown.
3. Belts and Pulleys are available through your local DV Systems Distributor.
When servicing the Air Compressor, shut off all power to the Unit, and drain the Tank
of air pressure. Always replace the Beltguard after adjusting the Belts or Pulleys.
Insist on Genuine DV
Systems parts and kits
when maintaining your
Compressor Unit and
Pump.