These include Tempervent air warmers, Roof Space 
Solar Gain and Automatic Summer Bypass.

To access the optional features (if fitted)

Touch Settings icon     then – 

INSTALLED OPTIONS > 

TEMPERVENT AIR WARMER 

or

 SOLAR GAIN 

or

 SUMMER 

VENT > ENABLE 

or

 DISABLE

On the “control screen” choose the method of control 
you wish to use and go through each step to set the 
control parameters – 

EXIT > EXIT

Some guidance on optional feature settings

The system will give you the ability to control the 
optional feature(s). These can include running the 
feature for a short period of time as and when you 
need to. This is called a Manual option. Alternatively, 
you may wish to run the optional feature(s) at a set 
time every day or night. This is called a Timer option. 
If you select this control option, you will then be 
asked to set up the timer appropriately. 

There is also the ability to activate the optional 
feature(s) using temperature as the activation 
method. If you choose that option, you will then be 
asked to set the temperature and so on. Of course, 
you are also able to have a combination of both 
temperature and time. All of these control settings 
are programmable by you in the Control Screen.

Recommended settings for optional features

Tempervent Air Warmer

In Cooler months

 – 

ENABLE

 (touch the Enable/Disable slide 

switch icon to change to Enable) 

> CONTROL

: = Temp & Timer 

(Set temp to 8

o

C) + Timer (ON 2100 / OFF 0700)

Note: The system fan speed will remain as programmed.

Note: This limits the time on and the air supply temperature 
below which the feature will operate.

In Warmer months

 – OFF

Roof Space Solar Gain

In Cooler months

 - ON - Mode = Temp (18

o

C) + Timer (ON 

1800 / OFF 2300) – Fan speed (High)

Note: This sets the roof space temperature above which the 
feature will operate and limits the time period it will operate 
in.

Additional Note: In the above example the solar gain 
function will begin when the roof space is above 18°C but 
only “IF” the house temperature is lower than 18°C.

In Warmer months

 - OFF

Auto Summer Vent Bypass

In Cooler Months

 - OFF

In Warmer Months

 - ON - Mode = Temp (suggested Temp 

setting 18 to 21 degrees) - Fan Speed = (MAX)

Note: The Summer Vent Bypass feature operates on a 
pre-set in-house temperature (measured at the control 
panel). When the in house temperature exceeds the pre-set 
temperature AND the air outside (measured by a remote 
sensor located outside the home) is cooler than the air at 
the control panel, the system will divert the incoming fresh 
air around the heat exchanger to increase the volume of 
fresher air being introduced.

Fan Speed setting 

The Fan Speed setting you choose for the above optional 
features is the fan speed the system will run at when the 
optional feature(s) is activated.

Other settings

The recommended settings for optional features above have 
proven to provide optimal operation for those features. You 
can choose alternative modes of operation and settings 
within the settings menus for each optional feature.

If system performance reduces, please revert to the 
recommended settings or call us on 0800 387 387.