CT-5320F/CT-5640F Fixed Thermal Camera QIG
8
Insert the cables and gland housing into the camera and attach them to
the connectors.
Figure 7: Installation Step 6 Illustration
Slide the gland housing chassis nut over the cables. Tighten the gland
housing chassis nut into the camera.
Figure 8: Installation Step 7 Illustration
Crimp the other end of the cables in place (not shown).
3.5.
Preparing the IP66 Enclosure
To prepare the camera for PoE power connection
Slide the Ethernet cable through the threaded end of the cable sealing
gland with the O-ring installed.
Use a scale to measure approximately 4-1/2” (114mm) of cable slack
from the end of the cable to the rubber grommet of the sealing gland.
Attach one open-end wrench onto the flange of the cable gland.
Using the second open wrench, tighten the compression nut to
approximately 8 in-lbs. (0.9 newton meters) of torque.
Summary of Contents for ioimage CT-5320F
Page 2: ...CT 5320F CT 5640F Fixed Thermal Camera QIG ii...
Page 22: ......