CT-5320F/CT-5640F Fixed Thermal Camera QIG
10
To prepare the camera for AC/DC power connections
Attach the male AC or DC five-pin terminal block connector to the AC
or DC power cables.
Figure 10: AC Power Installation
Figure 11: DC Power Installation
Insert the male connector into the female connector on the back of the
camera housing.
Figure 12: AC Power Cable Connections
Figure 13: DC Power Cable Connections
Pull the cables tightly back through the camera, exposing the thread of
the cable sealing gland out of the base of the camera.
Attach the electrical nut back onto the gland.
Tighten the nut securely until it is finger-tight.
Use the hex wrench to tighten the electrical nut to approximately
8 in-lbs. (0.9 newton meters) of torque.