AC/DC power: Connect the AC or DC male terminal block
connectors to the camera according to the wiring in section 3.5.
If you are powering the camera with an AC supply, insert the
green AC terminal block connector and connect AC+ to the
24VAC input and AC- to the 12VDC input
If you are powering the camera with a DC supply, insert the
white DC terminal block connector and connect DC+ to the
12VDC input and DC- (or ground) to the GND input
Caution:
DO NOT connect an AC supply to a DC connector. This
could damage the unit.
Attention:
Ne branchez pas une alimentation AC à un connecteur CC.
Ceci pourrait endommager la caméra.
Reconnect power to the existing cables.
Check for a steady LED indication on the Ethernet connector to confirm
connection to the IP network. The status LED indicators are:
LED 1: Steady green for 10MB connection or flashing green for
activity.
LED 2: Steady amber for 100MB connection or flashing amber for
activity.
Place the supplied white desiccant into the back cover.
Figure 15: Back Cover and White Desiccant