OPM BWT PERMAQ® Pico Rev. 2.0 EN
Devices and components | 3
EN
11
3.4 Configuration options
on/off
HR on/
off
on/off
FT
HR on/
off FT
Duo
Vario
Vario HR
Low-pressure RO mod-
ules
Yes
No
Yes
No
Yes
Yes
No
RO modules with in-
creased
salt retention (HR)
No
Yes
No
Yes
No
No
Yes
Flowmeter for
feed water
No
No
Yes
Yes
No
Yes
Yes
Flowmeter for
permeate
No
No
Yes
Yes
No
Yes
Yes
Dosing system
Option
Option
Option
Option
Option
Option
Option
Communication module Option
Option
Option
Option
Option
Option
Option
3.5 Scope of delivery
Fig.
4: Scope of delivery of BWT PERMAQ
®
Pico on/
off, HR on/off, on/off FT and Pico Vario
BWT PERMAQ
®
Pico on/off, HR on/off, on/off
FT and Pico Vario
•
1 x reverse osmosis device
•
3 x connection hoses
•
1 x circuit diagram
•
1 x installation and operating manual
•
1 x service inspection book
•
1 x filter element, PP-S (10") or PP-L (20")
depending on the device model
•
1 x filter key
Fig.
5: Scope of delivery of the BWT PERMAQ
®
Pico
Duo
BWT PERMAQ
®
Pico Duo
•
2 x reverse osmosis devices
•
6 x connection hoses
•
2 x circuit diagrams
•
2 x installation and operating manuals
•
2 x service inspection books
•
2 x pre-filters, PP-S (10") or PP-L (20") de-
pending on the device model
•
1 x filter key
•
1 x assembly connection set
Fig.
6: Scope of delivery of BWT PERMAQ
®
Pico
with AS dosing station
AS dosing system (optional)
•
Micro-dosing pump with suction lance and
inoculation point
•
Dosing hose
•
Connection cable (230
V)
•
Empty notification sensor
•
3
l dosing container
•
Holding bracket