7 | Operation
OPM BWT PERMAQ® Pico Rev. 2.0 EN
EN
26
7 Operation
7.1 Menu overview
•
OFF position
•
Operation/interval
•
Service menu
•
Test mode
•
Inspection mode
•
Disinfection int.
•
Disinfection ext.
•
Alarms/messages
The menu overview can only be viewed in the OFF position.
OFF position
The device is switched on and the control unit is in the
OFF
position. The device cannot be
switched on by an external signal (level). Immediately after you switch on the main switch, the
device remains in the
OFF
position and must then be put into operation by making the appro-
priate selection or choosing the
OK button
.
OFF
OPERATION/INTERVAL >
SERVICE MENU >
TEST MODE >
Following a power failure, the programme automatically returns to its position prior to the
power failure. Production is continued when requested. A power failure does not result in an
entry in the alarm history.
7.2 Automatic operation
The device is ready for operation and displays the
READY
status. If an external request signal is
received from the permeate tank, the device switches to the operating mode (
Ready Pro-
duction
).
READY
MENU
INTERVAL in _ _ : _ _
SW RO stop
Starting the programme sequence (automatic mode to production)
1) Switch on the
main switch
.
ð
The display shows the following menu screens one after the other:
BWT
Hand Held Terminal
Version 0.31
BWT PERMAQ PICO
System startup
Version: 5.30
Setup time: _ _
OFF
BWT PERMAQ PICO
continue
2) Press the
OK button
to open the main menu.