To View a Data Logger Recording

Once a data logger recording has been retrieved to the
LoggerStor you can view the information directly on the
LoggerStor screen. A data logger or printer does not have to
be attached to do this. You cannot, however, view a recording
while another recording is being retrieved or printed.

Press 

PRINT/DOWN ARROW

and

display will show a print or view
message for several seconds and then
change to the menu to select a Bin to
print or view. 

Use the 

RETRIEVE/UP ARROW

or 

PRINT/DOWN ARROW

to

scroll through the available Bins to select the recording you
wish to view.

When you have selected a Bin number to view, press

SET/MENU

.

The next menu will allow you to select
the temperature reading in Fahrenheit
or Celsius. 

Use the 

RETRIEVE/UP ARROW

and 

PRINT/DOWN ARROW

to select the temperature scale.

Press 

SET/MENU

to continue.

The LoggerStor will now prompt you
to select View or Print.

Press 

RETRIEVE/UP ARROW

to continue.

The final menu item is the option to select a filter function for
the information being viewed. If the user were to view a record-
ing which used all of the memory capacity of the data logger,
this would be a very long record of 8000 data samples for
LCL20 and LCL22 and 10,000 data samples for LCL10.
To  view this information would be a cumbersome and time-
consuming process. In most cases the information required
from the data recording is only when the temperature or
humidity has changed. If the temperature or humidity remains
constant, it is not necessary to view line after line of the same
information.

The LoggerStor allows the user to select from 1 to 10 degrees
of temperature change or 1 to 10% of humidity change to view.
Note that only ONE parameter may be used as a filter.

What this means is that data samples that are less than the
selected temperature or humidity change are ignored and only
when the temperature or humidity has changed by the
selected amount is a sample displayed. That temperature or
humidity becomes the new value to compare to and the
temperature or humidity will have to change again by the
selected amount before another sample is printed.

The display will show:

Press 

SET/MENU

to view all the temperature data or press

RETRIEVE/UP ARROW

to scroll from 1 to 10 degrees of

temperature filtering.

Press 

PRINT/DOWN ARROW

to do the same for the second

temperature probe if you are using a LCL22 or for humidity if

you are using a LCL20. After selecting the desired filter press

SET/MENU

to begin viewing the recording.

Use 

RETRIEVE/UP ARROW

and 

PRINT/DOWN ARROW

to

move through the recording samples.

You can exit the viewing function at any time by pressing

SET/MENU

.

Example Display

The LoggerStor uses a display with 16 characters by 2 lines.
As a result of this, the information displayed when viewing a
recording will be compacted to fit in the display. A typical
example of a LCL22 recording will look
like the  example to the right.

The first line of the display will show the temperature recorded
by probe #1 and the date in the month/day/year format. The
second line will show the temperature recorded by probe #2
and the time in the hours:minutes:seconds format. Note that
the 24 hour system is used in the LoggerStor.

Printing a Recording from the LoggerStor

Once a data logger recording has been retrieved to the
LoggerStor you can print the information directly to a printer. A
data logger does not have to be attached to do this. You
cannot, however, print a recording while another recording is
being retrieved or viewed. 

Press 

PRINT/DOWN ARROW

and the

display will show a print or view
message for several seconds and then
change to the menu to select a Bin  to
print or view.

Press 

RETRIEVE/UP ARROW

or 

PRINT/DOWN ARROW

to

scroll through the available Bins and select the recording you
wish to print.

When you have selected a Bin number to print, press

SET/MENU

The next menu will allow you to select
the temperature reading in Fahrenheit
or Celsius. 

Use the 

RETRIEVE/UP ARROW

and 

PRINT/DOWN ARROW

to select the temperature scale.

Press 

SET/MENU

to continue.

The LoggerStor will now prompt you
to select View or Print.

Press 

PRINT/DOWN ARROW

to continue.

The final menu item is the option to select a filter function for
the information being printed. If the user were to print a record-
ing, which used all of the memory capacity of the data logger,
this would be a very long record of 8000 data samples for the
LCL20 and LCL22 and 10,00 data samples for the LCL10—
about 120 pages of paper! To print this information would be
cumbersome and time-consuming process. In most cases the
information required from the data recording is only when the
temperature or humidity has changed. If the temperature or
humidity remains constant, it is not necessary to print line after

Print or View

Data from Bins

Select Bin #: 01

Dwyer Data Loggers

Temperature set

to Fahrenheit

Press UP to View

Press DOWN to Print

Send out all of 

The Temp 1 Data

67.26˚F 10/11/98

67.95˚F 03:24:50

Print or View

Data from Bins

Select Bin #: 01

Dwyer Data Loggers

Temperature set

To Fahrenheit

Press UP to View

Press DOWN to Print

Summary of Contents for LS1

Page 1: ...mation into Bins Each of the 31 Bins will hold a full logger recording This means that you can hold 31 logger recordings before you will have to record over a previously loaded Bin It is not neces sary to erase a given Bin to re use it Simply select the Bin you wish to re use and save the recording to it PHYSICAL DATA Storage Capacity Full recordings from up to 31 data loggers Logger Connection Cu...

Page 2: ...esired filter press SET MENU to begin viewing the recording Use RETRIEVE UP ARROW and PRINT DOWN ARROW to move through the recording samples You can exit the viewing function at any time by pressing SET MENU Example Display The LoggerStor uses a display with 16 characters by 2 lines As a result of this the information displayed when viewing a recording will be compacted to fit in the display A typ...

Page 3: ...or cannot change the user information A PC is required to do this To set a logger first plug it into the LoggerStor using the supplied cable The display will show the logger type and the first 16 char acters of the user message Press SET MENU and the display will change to the message to use the message to use the arrow keys After a short delay the display will then indicate the present sampling r...

Page 4: ... when the battery is exhausted it is strongly recommended to remove the battery to avoid damage to the LoggerStor from battery leakage USE ONLY ALKALINE BATTERIES IN THE LOGGERSTOR Substitution of a different battery can result in reduced perfor mance or permanent damage to this instrument To replace the LoggerStor s battery follow the steps below 1 Make sure the LoggerStor is OFF If you are using...

Reviews: