background image

Select one of the Bins to retrieve by pointing to the circle next
to the Bin number and clicking on it. When you have selected
a Bin to retrieve, click on OK to begin the retrieval process. The
LoggerStor will show a progress bar much like what is
displayed when retrieving information from a data logger. 

After the information has been retrieved from the LoggerStor, it
will be automatically displayed as an auto-scaled graph.

At this point the information can be treated the same as if it
were retrieved from a data logger. Refer to the instructions that
came the the LCL05 package to use the various options of the
LCL software. 

Erasing the LoggerStor Bins

A hidden option is available to erase all of the Bins in the
LoggerStor. This will completely remove all information stored
in every Bin. Start with the LoggerStor OFF.

Press and Hold 

RETRIEVE/UP ARROW

and 

PRINT/DOWN

ARROW

.

Press the ON button on the LoggerStor until the opening
message is visible.

After a brief delay the display will change to a clear memory
message. 

When this message is displayed release the 

RETRIEVE/UP

ARROW

and 

PRINT/DOWN ARROW

buttons.

The display will prompt the user to select the erase function or

to cancel.

Push the 

PRINT/DOWN ARROW

button to erase the informa-

tion stored in the LoggerStor Bins. Any other button will cancel
the erase function and return you to the opening menu.

Replacing the Battery in the LoggerStor

When the LoggerStor will not be used for an extended period,
or when the battery is exhausted, it is strongly recommended
to remove the battery to avoid damage to the LoggerStor from
battery leakage.

USE ONLY ALKALINE BATTERIES IN THE LOGGERSTOR.

Substitution of a different battery can result in reduced perfor-
mance or permanent damage to this instrument.

To replace the LoggerStor’s battery follow the steps below:

1. Make sure the LoggerStor is OFF. If you are using the 

optional AC adapter disconnect it now.

2. Remove the rear battery cover.
3. The battery and battery clip may be extended from the 

battery compartment to facilitate replacement.

4. Remove the battery from the battery clip and dispose of 

properly.

5. Line up the connector of the new battery and push onto the

pins of the battery clip with a firm motion. 

Do NOT reverse

the battery connection, even momentarily, as this can 
result in the loss of data or permanent damage to the 
logger.

6. Place the battery in the battery compartment of the 

LoggerStor.

7. Replace the battery cover.  

MAINTENANCE

No routine maintenance is required on the Model LS1 Data
Logger Storage. Please contact Dwyer Instruments, Inc. before
returning unit for repair to review information relative to your
application and obtain a return authorization number. When
returning a product to the factory, carefully package and ship
freight prepaid. Be sure to include a complete description of
the application and problem and identify any hazardous mate-
rial used with the product. 

DWYER INSTRUMENTS, INC.   

Phone: 219/879-8000

www.dwyer-inst.com

P.O. BOX 373 • MICHIGAN CITY, INDIANA 46361, ,U.S.A.     Fax: 219/872-9057

e-mail: info@dwyer-inst.com

Lit-By Fax: 888/891-4963

©Copyright 1999 Dwyer Instruments, Inc.

Printed in U.S.A.8/99

FR R1- 443116-00

21%

Summary of Contents for LS1

Page 1: ...mation into Bins Each of the 31 Bins will hold a full logger recording This means that you can hold 31 logger recordings before you will have to record over a previously loaded Bin It is not neces sary to erase a given Bin to re use it Simply select the Bin you wish to re use and save the recording to it PHYSICAL DATA Storage Capacity Full recordings from up to 31 data loggers Logger Connection Cu...

Page 2: ...esired filter press SET MENU to begin viewing the recording Use RETRIEVE UP ARROW and PRINT DOWN ARROW to move through the recording samples You can exit the viewing function at any time by pressing SET MENU Example Display The LoggerStor uses a display with 16 characters by 2 lines As a result of this the information displayed when viewing a recording will be compacted to fit in the display A typ...

Page 3: ...or cannot change the user information A PC is required to do this To set a logger first plug it into the LoggerStor using the supplied cable The display will show the logger type and the first 16 char acters of the user message Press SET MENU and the display will change to the message to use the message to use the arrow keys After a short delay the display will then indicate the present sampling r...

Page 4: ... when the battery is exhausted it is strongly recommended to remove the battery to avoid damage to the LoggerStor from battery leakage USE ONLY ALKALINE BATTERIES IN THE LOGGERSTOR Substitution of a different battery can result in reduced perfor mance or permanent damage to this instrument To replace the LoggerStor s battery follow the steps below 1 Make sure the LoggerStor is OFF If you are using...

Reviews: