background image

- 10 - 

 

Tinned Copper Braid 

Quality tinned copper braid in 5 widths for grounding applications. 

Preassembled

 

with lugs

 in selected widths and lengths - 

for both #10 and 1/4" bolt sizes. Contact Customer Service for special lengths or terminations. 

Sold per foot

 to 

accommodate almost any project. Very long per-foot lengths may not be continuous. Contact Customer Service to discuss 
your length needs if continuous length is required.  A major use of the Grounding Straps for amateur radio operators would 
be to ground one's rig, amp, etc. to a copper strip running behind the desk which acts as the central ground point for the 
equipment. This central point equipment ground would then be routed away with heavy copper strap to join any other 
similarly protected branches for SPG single point grounding. 
 
 

DXE Part Number

 

Description

 

DXE-TCB-100 

Braid Tinned Copper 1" wide Sold per ft  

DXE-TCB-075 

Braid Tinned Copper 3/4" wide Sold per ft  

DXE-TCB-063 

Braid Tinned Copper 5/8" wide Sold per ft  

DXE-TCB-050 

Braid Tinned Copper 1/2" wide, Sold per ft  

DXE-TCB-038 

Braid Tinned Copper 3/8" wide, Sold per ft  

DXE-TCB05-RT01 

Braid Tinned Copper 1/2" wide #10 ring terminals 1 ft  

DXE-TCB05-RT03 

Braid Tinned Copper 1/2" wide #10 ring terminals 3 ft  

DXE-TCB05-RT05 

Braid Tinned Copper 1/2" wide #10 ring terminals 5 ft  

DXE-TCB05-RT10 

Braid Tinned Copper 1/2" wide #10 ring terminals 10 ft  

DXE-TCB05-RT18I 

Braid Tinned Copper 1/2" wide 1/4" ring terminals 18"  

DXE-TCB05-RT24I 

Braid Tinned Copper 1/2" wide 1/4" ring terminals 24"  

DXE-TCB05-RT36I 

Braid Tinned Copper 1/2" wide 1/4" ring terminals 36"  

DXE-TCB075-RT18I 

Braid Tinned Copper 3/4" wide 1/4" ring terminals 18"  

DXE-TCB075-RT24I 

Braid Tinned Copper 3/4" wide 1/4" ring terminals 24"  

DXE-TCB075-RT03 

Braid Tinned Copper 3/4" wide 1/4" ring terminals 3 ft  

DXE-TCB10-RT01 

Braid Tinned Copper 1" wide 1/4" ring terminals 1 ft  

DXE-TCB10-RT18I 

Braid Tinned Copper 1" wide 1/4" ring terminals 18"  

DXE-TCB10-RT24I 

Braid Tinned Copper 1" wide 1/4" ring terminals 24"  

DXE-TCB10-RT03 

Braid Tinned Copper 1" wide 1/4" ring terminals 3 ft  

DXE-TCB10-RT05 

Braid Tinned Copper 1" wide 1/4" ring terminals 5 ft  

DXE-TCB10-RT10 

Braid Tinned Copper 1" wide 1/4" ring terminals 10 ft  

 
 
 
 
 

Coax Grounding Bracket, 1-1/2 inch V-bolt - DXE-CGB-150  
Coax Grounding Bracket, 2 inch V-bolt - DXE-CGB-200 

The DXE Coax Grounding Brackets are a versatile solution for providing additional grounding of the coaxial cable 
shields. The Stainless Steel brackets are supplied with a Stainless Steel V-bolt and hardware for fastening to tower 
legs or any tubular OD up to 2 inches. Each bracket has holes for two optional DXE-363-SST bulkhead connectors , 
two chassis mount SO-239 connectors or two DXE-1023 Type N bulkhead connectors - or combinations as needed.  
 
The Grounding Bracket is an ideal tower top junction point for the flexible antenna coax jumpers (often used to form 
a rotor loop) and the main runs down the tower leg. It may also be used at the base of the tower to provide a solid 
grounding point before the coax cable is routed away from the grounded tower.  

  
 

Summary of Contents for DXE-UE-2P

Page 1: ...tility Enclosure DXE UE 2P DXE UE 2P INS Rev 1 DX Engineering 2013 P O Box 1491 Akron OH 44309 1491 Phone 800 777 0703 Tech Support and International 330 572 3200 Fax 330 572 3279 E mail DXEngineering...

Page 2: ...coaxial cable One 2 x 1 2 x 1 8 thick copper strap clamp with two drilled holes Because this enclosure has many potential applications no holes have been drilled in the enclosure Mounting holes are p...

Page 3: ...own in Figure 2 If you are mounting to masonry install masonry anchors in the mortar joints and use the appropriate screws Toggle bolts or other specialty anchors may be needed depending on the mounti...

Page 4: ...tever you mount on the plate will fit once the plate is re mounted in the enclosure using the included four 8 x 1 2 screws When installing the plate insert and tighten the top 2 screws through the alu...

Page 5: ...ther wiring through the top couplers and bottom gaskets before installing connectors If you intend to use a copper strap to bond the aluminum plate to your Single Point Ground as shown in Figure 1 the...

Page 6: ...eather and insects as shown in Figure 5 Figure 5 Coaxial cable routed through bottom of enclosure Note In Figure 5 the smaller 75 receive protector DXE RLP 75FF shown on the left uses smaller diameter...

Page 7: ...male Connectors Bulkhead Mount 2 kW at HF 1 5 400MHz PPR IS B50LU C1 PolyPhaser Lightning Protector UHF Female Connectors Bulkhead Mount 375 Watts 50 700MHz PPR IS B50LU C0 PolyPhaser Lightning Protec...

Page 8: ...Watts Protector SO 239 ALF ATT3G50UHP Alpha Delta 500 MHz 2 kW Protector SO 239 ALF ATT3G50 Alpha Delta 3 GHz 200 Watts Protector N Connector ALF ATT3G50HP Alpha Delta 3 GHz 2 kW Protector N Connector...

Page 9: ...DXE 58R 112S 1 1 2 2 in Copper Strap Clamp to 5 8 in Ground Rod The DXE 58R 112S adaptor bonds 5 8 in ground rods to low impedance 1 1 2 in to 2 in copper strap for high performance grounding install...

Page 10: ...terminals 18 DXE TCB05 RT24I Braid Tinned Copper 1 2 wide 1 4 ring terminals 24 DXE TCB05 RT36I Braid Tinned Copper 1 2 wide 1 4 ring terminals 36 DXE TCB075 RT18I Braid Tinned Copper 3 4 wide 1 4 rin...

Page 11: ...copper or brass grounding material The kit accommodates a shield diameter of 1 4 to 2 1 8 The angle of the strap to the grounding material can be adjusted for the most direct path without a severe be...

Page 12: ...instructions for return to DX Engineering transportation charges prepaid by Buyer Every such claim for breach of these warranties shall be deemed to be waived by Buyer unless made in writing The above...

Reviews: