background image

- 11 - 

Stainless Steel V-Clamp w/ground lug, 1/2" to 3/4" pipe - DXE-SSVC-1PG 

This V-Saddle is made in one size that fits steel tubing, pipe or rod from 1/2 to 3/4'' OD as used in antenna 
construction. The supplied U-bolt is long enough to attach tubing to thick plates and is made with anti-corrosive 
properties. It is the same as the DXE-SSVC-1P except for the tab with hole for a 1/4" bolt for grounding purposes. 
A 1/4" stainless steel hex bolt and hardware are included. The special Stainless Steel saddle has serrated teeth will 
clamp to the pipe securely by biting into the surface. For this reason, it is not recommended for softer aluminum 
tubing or pipe. Ideal for clamping to a steel pipe or ground rod.  

 

Used to clamp 1/2 to 3/4'' (OD) steel tubing, pipe or rod  

 

Designed for attachments that don't require resistance to torque  

 

U-bolt and V-saddle made from high-strength 18-8* stainless steel  

   
 

Stainless Steel V-Clamp w/ground lug, 1" to 1-1/2" pipe - DXE-SSVC-150PG 

This V-Clamp is made in one size that fits Steel tubing or pipe from 1 to 1-1/2'' OD as used in antenna construction. 
The supplied V-bolt is long enough to attach tubing to thick plates and is made with anti-corrosive properties. It is the 
same as the DXE-SSVC-150P except for the tab with hole for a 1/4" bolt for grounding purposes. A 1/4" stainless 
steel hex bolt and hardware are included.  The special Stainless Steel saddle has serrated teeth will clamp to the pipe 
securely by biting into the surface. For this reason, it is not recommended for softer aluminum tubing or pipe.  
   U-Bolt thread dimensions: ¼"-20 x 1.5"  

 

Used to clamp 1 to 1-1/2'' (OD) steel tubing or pipe  

 

Designed for attachment to round steel support members  

 

V-bolt and saddle made from high-strength 18-8* stainless steel  

 
 
PolyPhaser Coax Shield Grounding Kit 1/4 to 2-1/8 in. Copper/Brass-to-Copper/Brass - PPR-UNI-KIT-2CC 

The PolyPhaser UNI-KIT-2CC provides a low inductance path for connecting a shield of copper or brass to 
copper or brass grounding material. The kit accommodates a shield diameter of 1/4 to 2 1/8''. The angle of the 
strap to the grounding material can be adjusted for the most direct path without a severe bend. Weather 
proofing kit for the cable shield is included.  

  
 
 
 

PolyPhaser Coax Shield Ground Kit 1/4 to 2-1/8 in. Copper/Brass-to-Aluminum/Tin/Galvanized Steel - PPR-
UNI-KIT-2CT 

The PolyPhaser UNI-KIT-2CT provides a low inductance path for connecting a shield of copper or brass to 
aluminum, tin or galvanized steel grounding material. The kit accommodates a shield diameter of 1/4 to 2 1/8''. 
The different metal for shield and ground connections prevents corrosion of the shield or ground rod due to 
dissimilar metals. The angle of the strap to the grounding material can be adjusted for the most direct path 
without a severe bend. Weather proofing kit for the cable shield is included.  

  
 

PolyPhaser Coax Shield Ground Kit 1/4 to 2-1/8 in. Aluminum/Tin/Galvanized Steel-to-Copper/Brass - PPR-
UNI-KIT-2TC 

 

The PolyPhaser UNI-KIT-2TC provides a low inductance path for connecting a shield of aluminum, tin or 
galvanized steel to copper or brass grounding material. The kit accommodates a shield diameter of 1/4 to 2 1/8''  
The different metals for shield and ground connections prevents corrosion of the shield or ground rod due to 
dissimilar metals. The angle of the strap to the grounding material can be adjusted for the most direct path 
without a severe bend. Weather proofing kit for the cable shield is included.  

 
 
 

PolyPhaser Coax Shield Ground Kit 1/4 to 2-1/8 in. Tin/Galvanized Steel-to-Tin/Galvanized Steel - PPR-UNI-
KIT-2TT 

The PolyPhaser UNI-KIT-2CT provides a low inductance path for connecting a shield of Tin, Aluminum or 
Galvanized Steel to Tin, Aluminum or Galvanized Steel grounding material. The kit accommodates a shield 
diameter of 1/4 to 2 1/8''. The different metal for shield and ground connections prevents corrosion of the shield or 
ground rod due to dissimilar metals. The angle of the strap to the grounding material can be adjusted for the most 
direct path without a severe bend.  Weather proofing kit for the cable shield is included.  

 

Summary of Contents for DXE-UE-2P

Page 1: ...tility Enclosure DXE UE 2P DXE UE 2P INS Rev 1 DX Engineering 2013 P O Box 1491 Akron OH 44309 1491 Phone 800 777 0703 Tech Support and International 330 572 3200 Fax 330 572 3279 E mail DXEngineering...

Page 2: ...coaxial cable One 2 x 1 2 x 1 8 thick copper strap clamp with two drilled holes Because this enclosure has many potential applications no holes have been drilled in the enclosure Mounting holes are p...

Page 3: ...own in Figure 2 If you are mounting to masonry install masonry anchors in the mortar joints and use the appropriate screws Toggle bolts or other specialty anchors may be needed depending on the mounti...

Page 4: ...tever you mount on the plate will fit once the plate is re mounted in the enclosure using the included four 8 x 1 2 screws When installing the plate insert and tighten the top 2 screws through the alu...

Page 5: ...ther wiring through the top couplers and bottom gaskets before installing connectors If you intend to use a copper strap to bond the aluminum plate to your Single Point Ground as shown in Figure 1 the...

Page 6: ...eather and insects as shown in Figure 5 Figure 5 Coaxial cable routed through bottom of enclosure Note In Figure 5 the smaller 75 receive protector DXE RLP 75FF shown on the left uses smaller diameter...

Page 7: ...male Connectors Bulkhead Mount 2 kW at HF 1 5 400MHz PPR IS B50LU C1 PolyPhaser Lightning Protector UHF Female Connectors Bulkhead Mount 375 Watts 50 700MHz PPR IS B50LU C0 PolyPhaser Lightning Protec...

Page 8: ...Watts Protector SO 239 ALF ATT3G50UHP Alpha Delta 500 MHz 2 kW Protector SO 239 ALF ATT3G50 Alpha Delta 3 GHz 200 Watts Protector N Connector ALF ATT3G50HP Alpha Delta 3 GHz 2 kW Protector N Connector...

Page 9: ...DXE 58R 112S 1 1 2 2 in Copper Strap Clamp to 5 8 in Ground Rod The DXE 58R 112S adaptor bonds 5 8 in ground rods to low impedance 1 1 2 in to 2 in copper strap for high performance grounding install...

Page 10: ...terminals 18 DXE TCB05 RT24I Braid Tinned Copper 1 2 wide 1 4 ring terminals 24 DXE TCB05 RT36I Braid Tinned Copper 1 2 wide 1 4 ring terminals 36 DXE TCB075 RT18I Braid Tinned Copper 3 4 wide 1 4 rin...

Page 11: ...copper or brass grounding material The kit accommodates a shield diameter of 1 4 to 2 1 8 The angle of the strap to the grounding material can be adjusted for the most direct path without a severe be...

Page 12: ...instructions for return to DX Engineering transportation charges prepaid by Buyer Every such claim for breach of these warranties shall be deemed to be waived by Buyer unless made in writing The above...

Reviews: