background image

- 12 - 

PolyPhaser Weatherproofing Kit - PPR-WK-1 

When a PolyPhaser model designed for inside use must be mounted outdoors and unprotected, use the 
weatherproofing kit to prevent moisture ingress. The kit can easily handle extreme temperatures and is unaffected 
by the sun's ultraviolet (UV) rays.  

 

Nonconductive  

 

Withstands -65F to +180F without cracking  

 

Water impermeable (MIL-S-19653A)  

 

Exceptional UV and salt spray resistance 

 
 
 

Permatex Dielectric grease, 3 oz - DXE-22058 

Dielectric grease is ideal for keeping moisture from entering your coaxial connectors. It also acts as a lubricant allowing 
easy connector removal by stopping corrosion of electrical connectors. Multi-use 3 oz package.

 

 

Safe for all RF connections.  

 
 
 
 
 
 
 

Technical Support 

 
If you have questions about this product, or if you experience difficulties during the installation, contact DX 
Engineering at (330) 572-3200.  You can also e-mail us at: 
 

DXEngineering@DXEngineering.com 

 

For best service, please take a few minutes to review this manual before you call. 

 
 
 
 
 

Warranty 

 

All products manufactured by DX Engineering are warranted to be free from defects in material and workmanship for a period of one (1) year from 
date of shipment. DX Engineering’s sole obligation under these warranties shall be to issue credit, repair or replace any item or part thereof which is 
proved to be other than as warranted; no allowance shall be made for any labor charges of Buyer for replacement of parts, adjustment or repairs, or 
any other  work, unless such charges are authorized in advance by DX Engineering.  If DX Engineering’s products are claimed to be defective in 
material or workmanship, DX Engineering shall, upon prompt notice thereof, issue shipping instructions for return to DX Engineering (transportation-
charges prepaid by Buyer). Every such claim for breach of these warranties shall be deemed to be waived by Buyer unless made in writing. The above 
warranties  shall  not  extend  to  any  products  or  parts  thereof  which  have  been  subjected  to  any  misuse  or  neglect,  damaged  by  accident,  rendered 
defective by reason of improper installation, damaged from severe weather including floods, or abnormal environmental conditions such as prolonged 
exposure to corrosives or power surges, or by the performance of repairs or alterations outside of our plant, and shall not apply to any goods or parts 
thereof  furnished  by  Buyer  or  acquired  from  others  at  Buyer’s  specifications.  In  addition,  DX  Engineering’s  warranties  do  not  extend  to  other 
equipment and parts manufactured by others except to the extent of the original manufacturer’s warranty to DX Engineering.  The obligations under 
the foregoing warranties are limited to the precise terms thereof. These warranties provide exclusive remedies, expressly in lieu of all other remedies 
including  claims  for  special  or  consequential  damages.  SELLER  NEITHER  MAKES  NOR  ASSUMES  ANY  OTHER  WARRANTY 
WHATSOEVER,  WHETHER  EXPRESS,  STATUTORY,  OR  IMPLIED,  INCLUDING  WARRANTIES  OF  MERCHANTABILITY  AND 
FITNESS, AND NO PERSON IS AUTHORIZED TO ASSUME FOR DX ENGINEERING ANY OBLIGATION OR LIABILITY NOT STRICTLY 
IN ACCORDANCE WITH THE FOREGOING. 
 
©DX Engineering 2013 
 
DX  Engineering®,  DXE®,  DX  Engineering,  Inc.®,  Hot  Rodz®,  Maxi-Core®,  DX  Engineering  THUNDERBOLT®,  DX  Engineering  Yagi 
Mechanical®, EZ-BUILD®, TELREX® and Gorilla Grip® Stainless Steel Boom Clamps, are trademarks of PDS Electronics, Inc. No license to use 
or  reproduce  any  of  these  trademarks  or  other  trademarks  is  given  or  implied.  All  other  brands  and  product  names  are  the  trademarks  of  their 
respective owners. 
 
Specifications subject to change without notice. 
 

 

Summary of Contents for DXE-UE-2P

Page 1: ...tility Enclosure DXE UE 2P DXE UE 2P INS Rev 1 DX Engineering 2013 P O Box 1491 Akron OH 44309 1491 Phone 800 777 0703 Tech Support and International 330 572 3200 Fax 330 572 3279 E mail DXEngineering...

Page 2: ...coaxial cable One 2 x 1 2 x 1 8 thick copper strap clamp with two drilled holes Because this enclosure has many potential applications no holes have been drilled in the enclosure Mounting holes are p...

Page 3: ...own in Figure 2 If you are mounting to masonry install masonry anchors in the mortar joints and use the appropriate screws Toggle bolts or other specialty anchors may be needed depending on the mounti...

Page 4: ...tever you mount on the plate will fit once the plate is re mounted in the enclosure using the included four 8 x 1 2 screws When installing the plate insert and tighten the top 2 screws through the alu...

Page 5: ...ther wiring through the top couplers and bottom gaskets before installing connectors If you intend to use a copper strap to bond the aluminum plate to your Single Point Ground as shown in Figure 1 the...

Page 6: ...eather and insects as shown in Figure 5 Figure 5 Coaxial cable routed through bottom of enclosure Note In Figure 5 the smaller 75 receive protector DXE RLP 75FF shown on the left uses smaller diameter...

Page 7: ...male Connectors Bulkhead Mount 2 kW at HF 1 5 400MHz PPR IS B50LU C1 PolyPhaser Lightning Protector UHF Female Connectors Bulkhead Mount 375 Watts 50 700MHz PPR IS B50LU C0 PolyPhaser Lightning Protec...

Page 8: ...Watts Protector SO 239 ALF ATT3G50UHP Alpha Delta 500 MHz 2 kW Protector SO 239 ALF ATT3G50 Alpha Delta 3 GHz 200 Watts Protector N Connector ALF ATT3G50HP Alpha Delta 3 GHz 2 kW Protector N Connector...

Page 9: ...DXE 58R 112S 1 1 2 2 in Copper Strap Clamp to 5 8 in Ground Rod The DXE 58R 112S adaptor bonds 5 8 in ground rods to low impedance 1 1 2 in to 2 in copper strap for high performance grounding install...

Page 10: ...terminals 18 DXE TCB05 RT24I Braid Tinned Copper 1 2 wide 1 4 ring terminals 24 DXE TCB05 RT36I Braid Tinned Copper 1 2 wide 1 4 ring terminals 36 DXE TCB075 RT18I Braid Tinned Copper 3 4 wide 1 4 rin...

Page 11: ...copper or brass grounding material The kit accommodates a shield diameter of 1 4 to 2 1 8 The angle of the strap to the grounding material can be adjusted for the most direct path without a severe be...

Page 12: ...instructions for return to DX Engineering transportation charges prepaid by Buyer Every such claim for breach of these warranties shall be deemed to be waived by Buyer unless made in writing The above...

Reviews: