 Before mounting any suppressor, clean the aluminum plate and the mounting tab on the 

suppressor. The DX Engineering Copper Cleaning kit 

DXE-CCK

 is highly recommended. It 

includes cleaning pads and copper joint compound which should be used between the suppressor 
mounting tab and the plate. This will assure a long-lasting corrosion-free joint. You could also use 
Penetrox A. 

DXE-P8A.

 

 Do not use star or other washers between the suppressor and the plate.  

 
When using the coaxial cable weather-tight couplers, use a 7/8" hole saw, available at most home 
supply stores, to make the proper size hole in the enclosure.  Check the hole alignment with the 
bottom access holes to make sure the coaxial cable or wiring will run in a straight line from bottom 
to top. Insert the coaxial cable or other wiring through the top couplers and bottom gaskets before 
installing connectors.              

 

If you intend to use a copper strap to bond the aluminum plate to your Single Point Ground as 
shown in 

Figure 1

, the included copper mounting bar is made to be used with 2” wide copper strap 

available from DX Engineering.  Drill the appropriate mounting holes (Suggested drill size is #29) 
in the plate. You can use the included #8 x 1/2” self-tapping screws to hold the clamp and strap to 
the plate.  You must clean the surfaces and use copper joint compound (included in the 

DXE-CCK

 

Cleaning kit) or Penetrox A 

DXE-P8A

 between the copper and the aluminum to ensure a long 

lasting, quality bond between the two dissimilar metals.  A two inch long slot would be cut through 
the enclosure for the 2 inch wide copper strap to go through as shown in 

Figure 4

 
 
 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 

Figure 4 - Shows optional 2 “ wide copper strap going through a customer cut slit in the 

enclosure and secured to the aluminum plate using the copper strap clamp. 

Summary of Contents for DXE-UE-2P

Page 1: ...tility Enclosure DXE UE 2P DXE UE 2P INS Rev 1 DX Engineering 2013 P O Box 1491 Akron OH 44309 1491 Phone 800 777 0703 Tech Support and International 330 572 3200 Fax 330 572 3279 E mail DXEngineering...

Page 2: ...coaxial cable One 2 x 1 2 x 1 8 thick copper strap clamp with two drilled holes Because this enclosure has many potential applications no holes have been drilled in the enclosure Mounting holes are p...

Page 3: ...own in Figure 2 If you are mounting to masonry install masonry anchors in the mortar joints and use the appropriate screws Toggle bolts or other specialty anchors may be needed depending on the mounti...

Page 4: ...tever you mount on the plate will fit once the plate is re mounted in the enclosure using the included four 8 x 1 2 screws When installing the plate insert and tighten the top 2 screws through the alu...

Page 5: ...ther wiring through the top couplers and bottom gaskets before installing connectors If you intend to use a copper strap to bond the aluminum plate to your Single Point Ground as shown in Figure 1 the...

Page 6: ...eather and insects as shown in Figure 5 Figure 5 Coaxial cable routed through bottom of enclosure Note In Figure 5 the smaller 75 receive protector DXE RLP 75FF shown on the left uses smaller diameter...

Page 7: ...male Connectors Bulkhead Mount 2 kW at HF 1 5 400MHz PPR IS B50LU C1 PolyPhaser Lightning Protector UHF Female Connectors Bulkhead Mount 375 Watts 50 700MHz PPR IS B50LU C0 PolyPhaser Lightning Protec...

Page 8: ...Watts Protector SO 239 ALF ATT3G50UHP Alpha Delta 500 MHz 2 kW Protector SO 239 ALF ATT3G50 Alpha Delta 3 GHz 200 Watts Protector N Connector ALF ATT3G50HP Alpha Delta 3 GHz 2 kW Protector N Connector...

Page 9: ...DXE 58R 112S 1 1 2 2 in Copper Strap Clamp to 5 8 in Ground Rod The DXE 58R 112S adaptor bonds 5 8 in ground rods to low impedance 1 1 2 in to 2 in copper strap for high performance grounding install...

Page 10: ...terminals 18 DXE TCB05 RT24I Braid Tinned Copper 1 2 wide 1 4 ring terminals 24 DXE TCB05 RT36I Braid Tinned Copper 1 2 wide 1 4 ring terminals 36 DXE TCB075 RT18I Braid Tinned Copper 3 4 wide 1 4 rin...

Page 11: ...copper or brass grounding material The kit accommodates a shield diameter of 1 4 to 2 1 8 The angle of the strap to the grounding material can be adjusted for the most direct path without a severe be...

Page 12: ...instructions for return to DX Engineering transportation charges prepaid by Buyer Every such claim for breach of these warranties shall be deemed to be waived by Buyer unless made in writing The above...

Reviews: