background image

- 7 - 

Optional Items 

 

DXE-CS2-25 / 50 / 100  -  Copper Strap Roll, 2 in. x 25 ft / 50 ft / 100 ft

 

Use ground strap to tie equipment back to a common ground point. Copper strap should also be used to make 
a non-resonant counterpoise for towers mounted on mountaintops or other rocky terrain.   Copper strap has 
lower inductance than wire so it is a better choice for providing ground paths.  

 

DXE Part Number

 

Description

 

DXE-CS2-25

 

Copper Strap Roll, 2 in. x 25 ft.

 

DXE-CS2-50

 

Copper Strap Roll, 2 in. x 50 ft.

 

DXE-CS2-100

 

Copper Strap Roll, 2 in. x 100 ft.

 

 

 

 

Polyphaser Coaxial Protectors - DC Blocked 

PolyPhaser Corp is the leading supplier of coaxial lightning protectors. These broadband protectors are for general, single 
transmitter use in the 1.5 to 400 MHz frequency range.  The lightning protectors are either bulkhead or flat surface 
(flange) mount.  The units use a dc-blocked gas tube design that has no dc continuity between the center pins. 
PolyPhaser's DC blocked products are designed to pass RF frequencies and block all DC. The protectors appear as a dc 
open between surge and protected ports and offer the best protection in the industry. 

 

DXE Part Number

 

Description

 

PPR-IS-50UX-C0

 

PolyPhaser Lightning Protector, UHF Female Connectors, Flange Mount, 2 kW at HF, 1.5-400MHz

 

PPR-IS-50UX-C1

 

PolyPhaser Lightning Protector, UHF Female Connectors, Flange Mount, 375 Watts, 50-700MHz

 

PPR-IS-50NX-C0

 

PolyPhaser Lightning Protector, N Female Connectors, Flange Mount, 2 kW at HF, 1.5-400MHz

 

PPR-IS-B50LN-C1

 

PolyPhaser Lightning Protector, N Female Connectors, Bulkhead Mount, 375 Watts, 50-700MHz

 

PPR-IS-B50LN-C0

 

PolyPhaser Lightning Protector, N Female Connectors, Bulkhead Mount, 2 kW at HF, 1.5-400MHz

 

PPR-IS-B50LU-C1

 

PolyPhaser Lightning Protector, UHF Female Connectors, Bulkhead Mount, 375 Watts, 50-700MHz

 

PPR-IS-B50LU-C0

 

PolyPhaser Lightning Protector, UHF Female Connectors, Bulkhead Mount, 2 kW at HF, 1.5-400MHz

 

PPR-IS-B50-HU-C1

 

PolyPhaser Lightning Protector, UHF Female Connectors, Bulkhead Mount, 500 W at VHF, 50-700MHz

 

PPR-IS-B50HU-C0

 

PolyPhaser Lightning Protector, UHF Female Connectors, Bulkhead Mount, 3 kW at HF, 1.5-400MHz

 

 

 

DXE-RLP-75FF  -  Receive Coaxial Protector - DC Pass-Through

 

Tii’s cutting edge In-Line® Coaxial Lightning Surge Protectors protect personnel and customer premises equipment, 
e.g. Televisions, Cable Set Top Boxes and Cable Modems from lightning and power induced surges on coaxial 
cables. They are specifically designed for today’s Broadband signals carried over the coax cables.  Tii's DC Pass 
products are designed to pass DC as well as a RF signal. These units may also be used where capacitive coupling 
(DC blocked) is not practical due to low frequency operation. 
 

 
DXE-CFT-1P/2P  -  Weatherproof Cable Feed Through for use with the Utility Enclosure 

6 weather-tight coax feed through couplers for use with the DXE-UE-2P Utility Enclosure and coax types with an 
outside jacket diameter ranging from .230” to .530”(1P) or .170” to .450” (2P) 

 

Color: Gray  

 

Cable DIA. Range: 

MIN-MAX ID: .230 in. to .530 in. (1P), 

 

MIN-MAX ID: .170 in. to .450 in. (2P)

 

 

Over all Length: 1.66 in. (1P) or 1.53 in. (2P) 

 

Thread Length: .45 in. (1P or .41 in. (2P) 

 

Thread OD: .886 (1P) or .804 (2P) 

 
 
PPR-IS-RCT  -   PolyPhaser Lightning Protector, Rotor Control, DC Shunt, 8 Lines, 60VAC

 

The IS-RCT is a lightning protector for 8 line rotor controllers and is used to protect controllers by preventing strike 
energy from entering the premise. 

 

Multi-strike Capability  

 

Faster Than Gas Tube  

 

Shunt Type Device for up to 8 Lines  

 

 

Summary of Contents for DXE-UE-2P

Page 1: ...tility Enclosure DXE UE 2P DXE UE 2P INS Rev 1 DX Engineering 2013 P O Box 1491 Akron OH 44309 1491 Phone 800 777 0703 Tech Support and International 330 572 3200 Fax 330 572 3279 E mail DXEngineering...

Page 2: ...coaxial cable One 2 x 1 2 x 1 8 thick copper strap clamp with two drilled holes Because this enclosure has many potential applications no holes have been drilled in the enclosure Mounting holes are p...

Page 3: ...own in Figure 2 If you are mounting to masonry install masonry anchors in the mortar joints and use the appropriate screws Toggle bolts or other specialty anchors may be needed depending on the mounti...

Page 4: ...tever you mount on the plate will fit once the plate is re mounted in the enclosure using the included four 8 x 1 2 screws When installing the plate insert and tighten the top 2 screws through the alu...

Page 5: ...ther wiring through the top couplers and bottom gaskets before installing connectors If you intend to use a copper strap to bond the aluminum plate to your Single Point Ground as shown in Figure 1 the...

Page 6: ...eather and insects as shown in Figure 5 Figure 5 Coaxial cable routed through bottom of enclosure Note In Figure 5 the smaller 75 receive protector DXE RLP 75FF shown on the left uses smaller diameter...

Page 7: ...male Connectors Bulkhead Mount 2 kW at HF 1 5 400MHz PPR IS B50LU C1 PolyPhaser Lightning Protector UHF Female Connectors Bulkhead Mount 375 Watts 50 700MHz PPR IS B50LU C0 PolyPhaser Lightning Protec...

Page 8: ...Watts Protector SO 239 ALF ATT3G50UHP Alpha Delta 500 MHz 2 kW Protector SO 239 ALF ATT3G50 Alpha Delta 3 GHz 200 Watts Protector N Connector ALF ATT3G50HP Alpha Delta 3 GHz 2 kW Protector N Connector...

Page 9: ...DXE 58R 112S 1 1 2 2 in Copper Strap Clamp to 5 8 in Ground Rod The DXE 58R 112S adaptor bonds 5 8 in ground rods to low impedance 1 1 2 in to 2 in copper strap for high performance grounding install...

Page 10: ...terminals 18 DXE TCB05 RT24I Braid Tinned Copper 1 2 wide 1 4 ring terminals 24 DXE TCB05 RT36I Braid Tinned Copper 1 2 wide 1 4 ring terminals 36 DXE TCB075 RT18I Braid Tinned Copper 3 4 wide 1 4 rin...

Page 11: ...copper or brass grounding material The kit accommodates a shield diameter of 1 4 to 2 1 8 The angle of the strap to the grounding material can be adjusted for the most direct path without a severe be...

Page 12: ...instructions for return to DX Engineering transportation charges prepaid by Buyer Every such claim for breach of these warranties shall be deemed to be waived by Buyer unless made in writing The above...

Reviews: