background image

- 9 - 

DXE-P8A  -  Penetrox A Anti-Oxidant - 8 oz Squeeze Bottle  

Use Penetrox A electrical joint compound to affect a substantial electrical connection between metal parts such 
as telescoping aluminum tubing or other antenna pieces. Assures high conductivity at all voltage levels by 
displacing moisture and preventing corrosion or oxidation.  For Aluminum to Aluminum, Aluminum to Copper 
or bare conductors.  Not recommended for use with rubber or polyethylene insulated wire.   
                     

*This part is classified hazardous and is limited to domestic UPS Ground shipping only

  

 
 
 
 

DXE-PPR Bonding Clamps 
                     

 

 
 

DXE Part Number

 

Description 

PPR-TK-1 

PolyPhaser Copper Strap to 5/8 through 1-1/4 in. Tower Leg Ground Clamp   

PPR-TK-2 

PolyPhaser Copper Strap to 1-1/4 through 2-1/4 in. Tower Leg Ground Clamp    

PPR-TK-3 

PolyPhaser Copper Strap to 2-1/4 through 3-3/4 in. Tower Leg Ground Clamp    

PPR-TK-4 

PolyPhaser Copper Strap to 3-1/2 through 5 in. Tower Leg Ground Clamp    

 
 

 
PolyPhaser #2 stranded - #10 solid Copper Wire to Copper Ground Rod Transition Clamps 

 

 

DXE Part Number

 

Description

 

PPR-J-1 

PolyPhaser #2 stranded thru #10 solid copper wire to 1/2 to 1-1/3 in. copper ground rod transition clamp    

PPR-J-2 

PolyPhaser #2 stranded thru #10 solid copper wire to 1-1/2 to 2-1/4 in. copper ground rod transition clamp    

 

 

DXE-58R-112S   1-1/2 - 2 in. Copper Strap Clamp to 5/8 in. Ground Rod 

The DXE-58R-112S adaptor bonds 5/8 in. ground rods to low impedance 1-1/2 in to 2 in. copper strap for high performance 
grounding installations.  
Copper strap must be cut and used to shim strap to rod clearance.    

 

Using this clamp is faster and easier than building up the joint for an exothermic weld  

 

1/4” 18-8 Stainless Steel hardware is included 

 
 

DXE-10C-112S   #1/0 - #6/0 AWG Copper Wire to 1-1/2 -  2 in. Copper Strap Bonding Clamp 

The DXE-10C-112S adaptor bonds #6/O AWG through #1/O AWG copper wire to low impedance 1-1/2 through 2 in. 
copper strap for high performance grounding installations  

 

Using this clamp is faster and easier than building up the joint for an exothermic weld  

 

1/4” 18-8 Stainless Steel hardware is included 

 

 
 

DXE-1C-112S   #6 - #1 AWG Copper Wire to 1-1/2 - 2 in. Copper Strap Bonding Clamp 

The DXE-1C-112S adaptor bonds #6 AWG through #1 AWG copper wire to low impedance 1-1/2 through 2 in. copper 
strap for high performance grounding installations.  

 

Using this clamp is faster and easier than building up the joint for an exothermic weld  

 

1/4” 18-8 Stainless Steel hardware is included 

 
 

DXE-MSC-3   1-1/2 - 2 in. Copper Strap to Copper Strap Bonding Clamp 

The DXE-MSC-3 bonds 1-1/2 through 2 in. copper strap to copper strap for high performance grounding 
installations.  

 

Using this clamp is faster and easier than building up the joint for an exothermic weld  

 

#10  18-8 Stainless Steel hardware is included 

Summary of Contents for DXE-UE-2P

Page 1: ...tility Enclosure DXE UE 2P DXE UE 2P INS Rev 1 DX Engineering 2013 P O Box 1491 Akron OH 44309 1491 Phone 800 777 0703 Tech Support and International 330 572 3200 Fax 330 572 3279 E mail DXEngineering...

Page 2: ...coaxial cable One 2 x 1 2 x 1 8 thick copper strap clamp with two drilled holes Because this enclosure has many potential applications no holes have been drilled in the enclosure Mounting holes are p...

Page 3: ...own in Figure 2 If you are mounting to masonry install masonry anchors in the mortar joints and use the appropriate screws Toggle bolts or other specialty anchors may be needed depending on the mounti...

Page 4: ...tever you mount on the plate will fit once the plate is re mounted in the enclosure using the included four 8 x 1 2 screws When installing the plate insert and tighten the top 2 screws through the alu...

Page 5: ...ther wiring through the top couplers and bottom gaskets before installing connectors If you intend to use a copper strap to bond the aluminum plate to your Single Point Ground as shown in Figure 1 the...

Page 6: ...eather and insects as shown in Figure 5 Figure 5 Coaxial cable routed through bottom of enclosure Note In Figure 5 the smaller 75 receive protector DXE RLP 75FF shown on the left uses smaller diameter...

Page 7: ...male Connectors Bulkhead Mount 2 kW at HF 1 5 400MHz PPR IS B50LU C1 PolyPhaser Lightning Protector UHF Female Connectors Bulkhead Mount 375 Watts 50 700MHz PPR IS B50LU C0 PolyPhaser Lightning Protec...

Page 8: ...Watts Protector SO 239 ALF ATT3G50UHP Alpha Delta 500 MHz 2 kW Protector SO 239 ALF ATT3G50 Alpha Delta 3 GHz 200 Watts Protector N Connector ALF ATT3G50HP Alpha Delta 3 GHz 2 kW Protector N Connector...

Page 9: ...DXE 58R 112S 1 1 2 2 in Copper Strap Clamp to 5 8 in Ground Rod The DXE 58R 112S adaptor bonds 5 8 in ground rods to low impedance 1 1 2 in to 2 in copper strap for high performance grounding install...

Page 10: ...terminals 18 DXE TCB05 RT24I Braid Tinned Copper 1 2 wide 1 4 ring terminals 24 DXE TCB05 RT36I Braid Tinned Copper 1 2 wide 1 4 ring terminals 36 DXE TCB075 RT18I Braid Tinned Copper 3 4 wide 1 4 rin...

Page 11: ...copper or brass grounding material The kit accommodates a shield diameter of 1 4 to 2 1 8 The angle of the strap to the grounding material can be adjusted for the most direct path without a severe be...

Page 12: ...instructions for return to DX Engineering transportation charges prepaid by Buyer Every such claim for breach of these warranties shall be deemed to be waived by Buyer unless made in writing The above...

Reviews: