Theory of Operation  

The 

RR8B-HP

 uses a star arrangement of 16 relays to select one or more of eight output ports when voltage 

is applied from an 8-wire control line. The 16 relays provide greatly improved power handling and SWR 
over conventional switches and allows port-to-port connections between any of the eight output ports.  

 
Installation

 

1.   Secure the switching unit using the included 

DXE-SSVC-2P

 V Saddle Clamp. 

For outdoor installations or in moist environments, connectors must face 
downward.

 

 
2.   Fasten all cables to the mounting mast or tower to relieve strain, and gently droop 

the cables to form a drip loop (do not use tight bends with coaxial cable). Install 
the 

RR8B-HP

 with the connectors facing down and use gradual bends or loops in 

heavy wires. If the

 RR8B-HP

 is mounted to a wooden pole or building, a wide 

copper flashing or heavy wire or strap should be connected from the mounting 
bracket to a good ground. 

 

 

Caution: 

Never switch antennas while transmitting. Hot switching with power will create a sustained 

arc that damages relay contacts. 

When switching ports, allow 15 ms before transmitting to avoid 

damaging the switch. This type of damage is NOT covered under warranty. 

 

3.   Wire the plug making a note of wire colors at each pin. Write them in 

the 

Connector Wire Reference Table 

below. Either "G" is ground. We 

recommend following standard resistor color codes, using ascending 
order by color. The color code is black 0, brown 1, red 2, orange 3, 
yellow 4, green 5, blue 6, violet 7, gray 8, and white 9.  

 

 

The green connector is in two parts and the top part can be removed by pulling it straight off. This will 
allow easier wire replacement or servicing as needed. When pushing the connector back in place, ensure 
you press straight inward. 

 
 
 
 
 
 

 

 

DXE-CW9

 Shielded CAT5 cable can be used. The shield is used as the signal ground return. Adhering 

to a logical standard allows people unfamiliar with a system to troubleshoot with minimal difficulty.  

 
 

For 

DXE-CW9

 shielded CAT5 cable we suggest working your way up through the pairs by ascending 

color: brown, brown/white, orange, orange/white, green, green/white, blue, and blue/white. 

 

Connector Wire Reference Table 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

The ground wire can be omitted if the 

DXE-EC-8

 control console or the 

DXE-CC-8A

 control console or 

other switching voltage source is grounded to the feedline. The feedline shield and equipment grounds 
provide the ground path.

 

Note: The 

total loop resistance of the control cable path must be under 30 

ohms for reliable operation. 

Summary of Contents for RR8B-HP

Page 1: ...ntenna Switch DXE RR8B HP INS Revision 2c DX Engineering 2017 1200 Southeast Ave Tallmadge OH 44278 USA Phone 800 777 0703 Technical Support and International 330 572 3200 Fax 330 572 3279 E mail DXEngineering DXEngineering com ...

Page 2: ... Enclosed 20 ampere RF relays Safe 12 volt relay operation MOV surge protection on control lines Specifications Power Rating 7kW ICAS all modes under 2 1 SWR 5 kW CCS all modes under 2 1 SWR Control Voltage 10 14 Vdc at 100 mA Port to Port Isolation 70 dB below 30 MHz 55 dB below 60 MHz Loss 0 1 dB below 60 MHz Impedance 50 ohms Dimensions 10 375 x 9 875 x 4 375 and the mounting flange hangs down ...

Page 3: ...pe of damage is NOT covered under warranty 3 Wire the plug making a note of wire colors at each pin Write them in the Connector Wire Reference Table below Either G is ground We recommend following standard resistor color codes using ascending order by color The color code is black 0 brown 1 red 2 orange 3 yellow 4 green 5 blue 6 violet 7 gray 8 and white 9 The green connector is in two parts and t...

Page 4: ...f parts adjustment or repairs or any other work unless such charges are authorized in advance by DX Engineering If DX Engineering s products are claimed to be defective in material or workmanship DX Engineering shall upon prompt notice thereof issue shipping instructions for return to DX Engineering transportation charges prepaid by Buyer Every such claim for breach of these warranties shall be de...

Reviews: